Satya S. Patra1, Lelitha Devi Vanajakshi This email address is being protected from spambots. You need JavaScript enabled to view it.2 1 Lyles School of Civil Engineering, Purdue University, West Lafayette 47906, USA
2 Department of Civil Engineering, IIT Madras, Chennai 600036, India
Received:
May 6, 2021
Copyright The Author(s). This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.
Revised:
September 13, 2021
Accepted:
September 16, 2021
Download Citation:
||https://doi.org/10.4209/aaqr.210104
Patra, S.S., Vanajakshi, L.D. (2021). Analysis of the Near-road Fine Particulate Exposure to Pedestrians at Varying Heights. Aerosol Air Qual. Res. 21, 210104. https://doi.org/10.4209/aaqr.210104
Cite this article:
Scientific literature has overlooked how PM2.5 concentrations vary with varying pedestrian heights near a roadway. Understanding this is important because walking is an essential commuting element of a sustainable transportation system, and pedestrians’ height varies widely. Therefore, the focus of the current study is to bridge this gap using results from CALINE 4 model and mobile PM2.5 measurements. In CALINE 4, a simple pedestrian pathway depicting the selected study site located near the Sardar Patel Road, Chennai, India, was simulated. The PM2.5 concentrations were estimated on this pathway at varying heights (0.1–1.8 m) in 135 simulated runs. Subsequently, the sensitivity of the PM2.5 exposure difference across heights was explored with varying ambient PM2.5 concentrations, wind speed, traffic volume, and traffic compositions. Results indicated that the PM2.5 concentrations reduced with increasing heights of pedestrians in all the modelled runs. When this PM2.5 exposure difference was investigated with varying surrounding conditions, it was found that the difference in PM2.5 exposure across heights was influenced by the wind speed, traffic volume, and traffic composition. Ambient PM2.5 concentrations had no discernible effect on it. Car-dominated traffic with a higher mode share of heavy commercial vehicles was marked with the highest PM2.5 exposure difference across heights. For traffic volume, it was observed that for every 100 vehicles hr–1 increase in traffic volume, the PM2.5 exposure difference increased by 0.13 µg m–3 m–1 in the range of pedestrian’s height. For wind speed, calculations suggested that for every 1 m s–1 increase in wind speed, the PM2.5 exposure difference was reduced by 0.095 µg m–3 m–1 in the range of pedestrian’s height. Finally, to bolster the modelling results, mobile PM2.5 measurements (using portable, low-cost optical particle sensors) were conducted near a busy urban roadway at two different heights, 80 cm and 150 cm, during peak and off-peak hours. The results of mobile measurements were found to be consistent with CALINE 4 modelled results.HIGHLIGHTS
ABSTRACT
Keywords:
PM2.5, CALINE 4, Pedestrian exposure, Exposure gradient
Ambient air pollution is a significant environmental problem threatening several lives. Epidemiological studies have provided substantial evidence relating routine ambient air pollution exposure to adverse health outcomes (Atkinson et al., 2016; Nawahda et al., 2012; Patra et al., 2021c). Overall, one out of ten deaths worldwide could be attributed to air pollution (Guilbert et al., 2019). World Health Organization (WHO) estimates that about 91% of the world's population resides in areas where air quality exceeds the prescribed limits (WHO, 2021). Road traffic is one of the primary sources contributing to this deteriorated air quality in urban areas (Carvalho et al., 2018; Hassanpour Matikolaei et al., 2019; Kanok and Waheed, 2006; Matz et al., 2019). Traffic-related air pollution is a unique combination of particles and gaseous compounds that can come directly from tailpipe exhaust, tire and brake wear, road dust re-suspension, and secondary aerosols (Amouei Torkmahalleh et al., 2020). Concerns about traffic-related air pollution are higher because emissions occur at lower heights, contributing to surface pollution (Guilbert et al., 2019). Amongst the major traffic-related pollutants, Particulate Matter (PM) is identified as a major component, which is the leading cause of infant mortality and affects more people than any other pollutants (Wang et al., 2020). Commuters close to traffic face elevated levels of fine particulate (PM2.5; particulate matter having a size less than 2.5 µm) concentrations (Kumar and Goel, 2016). The situation is worsening as the vehicle population increases worldwide, along with an increase in vehicle kilometres travelled and traffic congestion. Therefore, it has become the need of the hour to understand and characterize the traffic-related PM concentrations at different commuting conditions. Walking is an essential commuting element of a sustainable transportation system, which reduces dependency on motorized vehicles, fosters community living, and enhances the local economy (Luo et al., 2018). It also helps maintain individual fitness and improves public health (Laverty et al., 2013). However, with the increasing number of motorized traffic on roads, pedestrians are forced to walk by streets with heavy traffic and are exposed to elevated fine particulate levels. Consequently, several researchers have attempted to understand the factors influencing pedestrians’ exposure to PM2.5. In Delhi, India, a study reported that the measured on-road PM2.5 concentrations exceeded the ambient PM2.5 levels by an average of 40% (Goel et al., 2015). Recent research in Singapore has shown that pedestrian particle exposure is the worst among other commuting modes (Tan et al., 2017). Literature suggests pedestrian routes marked with heavy traffic congestion, bus stops, or traffic intersections are associated with higher levels of PM2.5 (Boarnet et al., 2011; Goel and Kumar, 2015; Greaves et al., 2008; Qiu and Li, 2015; Schneider et al., 2015; SM et al., 2019). Qui and Li (2015) indicated that PM2.5 exposure to pedestrians is also influenced by the intersection design. Another study reported that both underpass and overpass intersections reduce pedestrians’ PM2.5 exposure significantly (Qiu and Peng, 2015). In addition, researchers have indicated that the hour of commuting also influences the PM2.5 pedestrian exposure. For example, Quiros et al. (2013) reported that PM2.5 exposure for pedestrians during evening hours is less than morning and afternoon hours. Besides, apart from surrounding conditions and the time of the day, meteorological variables such as wind speed and wind direction are also reported to affect the PM exposure levels. In general, as wind speed increases, dispersion occurs both vertically and along the wind direction, influencing PM concentrations both horizontally and vertically (Conte et al., 2018; Holmes et al., 2005; Molnár et al., 2002). While several studies on pedestrians’ exposure to fine particulates have been published, most of them focus on understanding the variation of PM2.5 levels with commuting conditions, traffic volume, and meteorology. However, a key aspect, i.e., the variability of PM2.5 exposure for different pedestrian heights, has been overlooked. Naively one may expect that pedestrians with shorter height are exposed to higher pollutant concentrations than the tall pedestrians while walking along a busy roadway, on account of their breathing zone being closer to the vehicle exhausts. Studies have been reported in the literature that suggests a significantly lower concentration of pollutants at higher floors relative to ground floors (Goel and Kumar, 2016). However, similar evaluation for different pedestrian heights has received little critical attention in the scientific literature. It is crucial to consider this aspect because the heights vary widely between children and adults. Knowing the vertical gradient of PM2.5 exposure across this range can provide valuable insights into potential health risks. Certain limited literature suggests that the concentration of particles and carbon monoxide is greater at a child's height than at an adult's height near roadways (Kaur et al., 2007; Wang et al., 2021). However, the factors influencing this concentration difference have not been investigated. Therefore, the current study aims to understand how PM2.5 exposure varies with different pedestrian heights near urban roadways, and explores how this exposure difference varies with varying traffic volume, wind speed, traffic composition, and ambient PM2.5 concentration. For the same, a Gaussian plume line source model, CALINE 4 (Benson, 1988; Fung et al., 2013), is used. Finally, mobile PM2.5 measurements were conducted near a busy arterial in Chennai, India, to experimentally verify the simulation results. Numerous methods are available to measure particle mass concentrations. The U.S. Environmental Protection Agency (U.S. EPA) has set the gravimetric filter method as a reference to measure PM2.5 levels (U.S. EPA, 1997). These methods are accurate and precise but are not capable of providing temporal information (Sousan et al., 2016a). Another method, namely Cascade impactors, utilize a combination of the gravimetric method and chemical analysis to determine particle mass (Hinds, 1999). Microscopy is another highly accurate method for determining particle mass concentration. However, all these methods are labor-intensive, time-consuming, and expensive. Another set of instruments exist that calculate the particle mass indirectly by estimating the particle number concentration. Examples of such instruments are scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) (Sousan et al., 2016a). These instruments make appropriate assumptions about particle density to measure the mass concentration. While these methods are fast and automatic, their expensive nature makes them impractical for personal exposure evaluations. For the same, optical particle counters are used. Optical instruments measure the intensity of light scattered by aerosol particles, which is used to estimate the particle mass concentrations (Hinds, 1999). Mobile PM measurements using optical particle counters are quite feasible due to their low-cost and portable nature, making it easy to collect data by carrying it during the daily commute. Consequently, the use of low-cost sensors for urban surveillance and personal exposure studies in the scientific community has been growing recently. For instance, low-cost PM sensors have been used in various environments such as residential and occupational environments (Krause et al., 2019; Merico et al., 2019; Moreno-Rangel et al., 2018; Omidvarborna et al., 2021; Patra et al., 2021c), traffic environments (Chen et al., 2019; Forehead et al., 2020), and urban hotspots (Feenstra et al., 2019; Lim et al., 2019; Magi et al., 2019; SM et al., 2019). The network-wide implementation of low-cost sensors to obtain high spatio-temporal resolution data on PM2.5 has also gained popularity (Bi et al., 2020; Datta et al., 2020; Gao et al., 2015; Zikova et al., 2017). The current study uses two low-cost optical PM2.5 sensors (Models: Sensiron SPS30 and Panasonic PM2.5) for outdoor mobile PM2.5 measurements, which need elaborate calibration to have high accuracy. Due to the lack of availability of two portable low-cost PM2.5 sensor units from the same manufacturer during the study, the measurements were conducted using two different low-cost PM2.5 sensors, which are similar in performance. The selected sensors use the same measurement techniques and have identical detection limits. Additionally, to ensure agreement, numerous co-location tests were performed between the sensors and also with a laboratory-grade particle counter. However, in this study, the outdoor co-location was done for only a limited period. Because of this, the study makes no attempt to comment on any quantitative estimation of PM2.5 differences between pedestrians of varying heights. It only compares the values to understand the relative impact. Overall, the study presents a novel examination of PM2.5 concentration variation across the height of pedestrians that has been overlooked in the pedestrians’ pollutant concertation evaluation literature. The approach and execution adopted in this study can be grouped into two categories. They are CALINE 4 Simulation and mobile measurements. The following sections outline the research methodologies for both these categories. The current study aims to understand how PM2.5 concentration changes with changing pedestrian heights near roadways. For the same, the California Line Source Dispersion Model (CALINE 4) is used. CALINE 4 is the most widely used vehicular pollutant dispersion model (Dhyani et al., 2013). It is a line-source air quality model developed by the California Department of Transportation. It employs the Gaussian diffusion equation and the mixing zone concept to model traffic pollutant dispersion (Benson, 1984). The model discretizes a roadway link into series of finite segments, then estimates the pollutant concentration in each segment, and finally adds up those estimates to determine the pollutant concentration for a specific receptor position (Majumdar et al., 2008). The concentration at a receptor point (x, y, z) is calculated using Eq. (1) (Chen et al., 2009). where, C is the concentration of pollutant; q is the line source’s length; σy and σz are the horizontal and vertical Gaussian dispersion parameters; H is the source height; and y1 and y2 are the endpoints of the divided finite line sources. Evaluation studies have been performed assessing how well the CALINE 4 simulated pollutant concentrations match the real-world emissions. Agharkar (2017) compared the PM2.5 concentrations forecasted by CALINE 4 in the City of Cincinnati and reported good agreement (p = 0.9482) with the measured on-site data. Goud et al. (2015) evaluated the performance of CALINE 4 to estimate the PM2.5 concentration at a traffic intersection in Bangalore, India and reported the performance to be valid and acceptable. Prakash et al. (2016) predicted the PM10 concentrations along a highway in Mysuru, India, and reported the predicted concentrations to be comparable with the monitored values (R2 = 0.943). Besides good modelling functionality, CALINE 4 offers several advantages over other pollutant dispersion models, such as the need for lesser input data, smooth user interface, and ability to reliably predict air quality up to 500 m (Dhyani et al., 2013; Dhyani and Sharma, 2017; Majumdar et al., 2010). The abovementioned advantages motivated the use of CALINE 4 in the current study to explore the vertical difference in PM2.5 concentrations near roadways in the range of pedestrian height. However, a major limitation of the CALINE 4 model is that the Gaussian dispersion model does not incorporate the recent developments in turbulence theory (Batterman et al., 2010). Also, CALINE 4 does not model the non-exhaust portion of traffic-related particle emissions (Chen et al., 2009). A simple 3-lane link geometry (shown in Fig. 1) was used as an input in the CALINE 4 model. Nineteen receptors (points where PM2.5 concentrations were calculated as the output of the model) were placed at a lateral distance of 6 m from the drawn link, each separated by a distance of 10 cm in the vertical direction. Overall, the PM2.5 concentrations up to a height of 180 cm were analyzed. Different input conditions were used to run the CALINE 4 model. This was done to understand the sensitivity of the vertical differences in PM2.5 across the receptor points with changing surrounding conditions. For the same, three regimes (Low, Medium, and High) of wind speed and ambient PM2.5 concentrations were considered in the analysis. Similarly, three regimes for traffic volumes were also considered. The values corresponding to each regime for these variables are summarized in Table 1. These values were chosen because the average PM2.5 concentration of Chennai is 33 µg m–3 (Chen et al., 2020); the traffic volume in the stretch during peak hour is around 2300 vehicles h–1 (Sampathkumar et al., 2018); and, the wind speed referring to Beaufort scale of light and gentle breeze in low wind speed category, moderate breeze in medium wind speed category, and Fresh and strong breeze in high wind speed category (Salvacao et al., 2015). In addition to these input parameters, the effect of traffic composition on the vertical differences in PM2.5 was also explored. To do so, five categories of traffic compositions were included. They were, Category I (Car-60%, 2-Wheeler (2W)-20%, Light Commercial Vehicles (LCV)-10%, and Heavy Commercial Vehicles (HCV)-10%), Category II (Car-20%, 2W -60%, LCV-10% and HCV-10%), Category III (Car-40%, 2W-40%, LCV-10% and HCV-10%), Category IV (Car-60%, 2W-20%, LCV-5% and HCV-15%), and Category V (Car-20%, 2W-60%, LCV-5% and HCV-15%). The emission factors of PM2.5 for each vehicle type were taken from the Automotive Research Association of India (ARAI, 2007). For each CALINE 4 model run, one regime from each input variable (listed in Table 1) was chosen along with a vehicle composition category. For instance—medium ambient PM2.5 concentrations with low wind speeds and high traffic volume with Category III composition. Therefore, considering all the permutations, a total of 135 simulated runs were performed, and the concentrations of PM2.5 at receptors in each run were recorded. These concentrations were reported as an hourly average concentration by the model. Finally, exploratory analysis using comparison plots was performed to examine the near-roadway vertical differences in PM2.5 concentrations up to 180 cm height, and to see how these differences changed with changing ambient PM2.5 concentration, wind speed, traffic volume, and traffic composition. To understand the sensitivity of vertical differences in PM2.5 concentrations with respect to individual parameters (vehicle volume, traffic composition, wind speed, and ambient PM2.5 concentrations), a gradient variable (G) as shown in Eq. (2) is introduced and calculated for each simulation. This value is introduced because the absolute numerical value of G indicates the steepness of PM2.5 concentration across height, i.e., if the absolute numerical value of G is higher, the difference in PM2.5 concentration between lower and higher heights is more. Here, a and b are the upper and lower limits of receptor points in the CALINE 4 model, which are 1.8 m and 0.1 m, respectively. (PM2.5)x represents the PM2.5 concentration at the receptor at x m height. To understand the effect of each individual variable on the difference in PM2.5 concentration across height, G was calculated for different simulations where the value of the variable of interest (for instance: traffic volume) was increased sequentially while keeping the values of other variables constant. Subsequently, the G was calculated for each changing value of the variable of interest and analyzed. Along with the simulated results, as discussed before, mobile PM2.5 measurements were also performed near an urban roadway at different heights to bolster the findings. This section discusses the materials and methodology adopted for mobile measurements. Two portable, low-cost particle sensors were used for mobile measurements in this study; they were Sensiron SPS30 and Panasonic PM2.5 sensor. Sensiron SPS30 is a low-cost optical PM2.5 sensor with dimensions ~41 mm × 41 mm × 12 mm (Sensiron, 2018). This portable, low-cost optical PM2.5 sensor can measure mass concentrations in the 1–1000 µg m–3 range. SPS30 samples air with a small integrated fan, with a minimum sampling interval of one second. The counting efficiency of the SPS30 comes pre-calibrated with potassium chloride salt particles and TSI DustTrakTM DRX Aerosol Monitor 8533 as a reference (Sensiron, 2018). To interface and download the collected data from SPS30, a Raspberry Pi 4 single-board microprocessor was used. A custom python program built on top of an open-source python library – Raspi Driver SPS30 developed by UnravelTEC (UnravelTEC, 2019) was written to read, write, and store the output of the SPS30 on the local memory of Raspberry Pi 4. The other PM2.5 sensor, Panasonic PM2.5 (Nakayama et al., 2018), has nearly similar specifications as the SPS30 sensor. This sensor was developed at Panasonic labs in Japan and was recently calibrated for Indian conditions. The Panasonic PM2.5 sensor came with a mobile application to log the sensor’s output. The sampling interval for both the sensors was set to be 1 minute. To evaluate the performance of both of the low-cost PM sensors, they were co-located against each other, and also with respect to a lab-grade portable aerosol spectrometer, PAS 1.109, manufactured by the GRIMM (GRIMM, 2010). GRIMM PAS 1.109 is a state-of-the-art optical particle counter that measures particle number concentrations in 32 bins. It employs a laser at 0.5 mW to detect large particles and 30 mW to detect small particles. The PM2.5 output of the GRIMM instrument was recently calibrated before the data collection campaign. The performance of the GRIMM PAS has been previously assessed in the literature (Crilley et al., 2018; Dinoi et al., 2017). All the co-location experiments in this study were performed in both indoor and outdoor conditions and are further discussed in the next subsection. Statistical tests were performed to quantify the assessment. This study conducted three kinds of sensor co-location experiments. Firstly, both the SPS30 and Panasonic PM2.5 sensors were co-located against the GRIMM PAS 1.109 in indoor and outdoor conditions. The location selected for indoor experiments was a well-ventilated air-conditioned room—ITS laboratory, IIT Madras, which has moderate activity levels throughout the working hours (9 AM–6 PM) in a day. The outdoor co-location was performed on a pedestrian pathway located near the Sardar Patel Road, Chennai, India (the characteristic of location is discussed in the following sub-section). The aim of these co-locations was to assess the performance of the low-cost sensors relative to a state-of-the-art PM reference instrument. Secondly, the SPS30 and Panasonic PM2.5 sensors were co-located against each other. This co-location was meant to check the agreeability of low-cost sensors’ outputs under identical conditions. These intra-sensor co-locations were carried out in both indoor and outdoor environments. For outdoor co-location, the SPS30 and Panasonic PM2.5 were carried by volunteers while walking, keeping both the sensors at the same elevation. Finally, the third set of co-location experiments were performed before every field data collection. This was done to validate the sensors’ performance before field measurements and ensure agreeability between both the sensors. The co-location experiments in this set involved both intra-sensor co-location and co-location relative to the reference instrument, GRIMM PAS 1.109. With respect to the reference instrument, the co-locations for both the sensors were performed in the ITS laboratory. For intra-sensor co-location, outdoor experiments were conducted at the data collection site, where volunteers carried both the sensors at the same height, and the corresponding outputs were compared. The evaluation of intra-sensor co-location was performed by calculating the coefficient of variation (CV) for both the sensors’ outputs. The coefficient of variation is usually used to determine the intra-sensor variability in measurements (Crilley et al., 2018). Eq. (3) was used for calculating the same. Here, σ is the standard deviation, and µ is the mean of the PM2.5 measurements from both the sensors. Acceptable values of CV for the two similar sensors, according to U.S. EPA, are up to 0.1 (Sousan et al., 2016b). For co-location experiments relative to the reference instrument, the Pearson correlation coefficient (r) was calculated between the sensor’s output and the reference instrument’s output. Pearson correlation coefficient (r) values > 0.97 are acceptable between a test instrument and a reference instrument (Sousan et al., 2016b). In addition to these accuracy metrics, statistical t-tests were also conducted to assess any statistical significance of the difference in intra-sensor, or sensor and reference instrument’s output. One-minute average data from each of the sensors for the entire duration of the experiments were used for all the t-tests (n > 30). The R-Studio software was used for the t-test. These t-tests were conducted at 95% confidence with the null hypothesis as no difference in output and the alternative hypothesis as a difference in reading prevails. P-values greater than 0.05 for t-tests suggest null hypothesis acceptance, and less than 0.05 indicate alternative hypothesis acceptance. Overall, rigorous evaluations were performed for the low-cost sensors to ensure agreeability in their measurements. The field PM2.5 data collection was conducted on a pedestrian pathway located near the Sardar Patel Road, Chennai, India. The selected pathway is nearly 70m in length. This particular pathway was selected for the experiments because it is situated near a busy urban road (Patra et al., 2021a; Sakhare and Vanajakshi, 2020) and is free from any interference from shops or buildings. The exposure of fine particulates to pedestrians on it can, therefore, be assumed to be primarily due to the adjacent traffic movements. Fig. 2 shows the study site used. For mobile PM2.5 measurements, a volunteer traversed the pathway with the SPS30 sensor mounted at the height of 150 cm and the Panasonic sensor tied at the height of 80 cm from the ground level. The position of both the sensors on the volunteer while collecting the PM2.5 data is shown in Fig. 3. While the sensors were mounted, as shown in Fig. 3, the volunteer travelled back and forth thirty trips on the pathway (Fig. 2). To ensure repeatability, another round of data collection, in the same manner, was carried out another day. The data regarding ambient PM2.5 were collected from a ground-level Central Pollution Control Board (CPCB) monitoring station (CPCB, 2020), located nearly 300 m away from the selected measurement site. Apart from this, the wind speed information at the field data collection site was downloaded from the NCEP/NCAR reanalysis dataset provided by the NOAA Physical Sciences Laboratory (PSL) (https://psl.noaa.gov/). This reanalysis is a state-of-the-art forecast method to assimilate meteorological information using data from 1948 to the present (Kalnay et al., 1996). The spatial coverage of the PSL dataset is 2.5° × 2.5° on global grids. The measurement site is located in between 13.0068°N, 80.2000°E and 13.0068°N, 80.4500°E. The corresponding surface-level wind speed data was downloaded for this grid. One thing to note here is that, due to lack of instrumentation, it was not possible to obtain the traffic volume data during both the data collection days. The data collection was performed on 29th January 2020 at 10 AM and 31st January 2020 at 2 PM. These were the methodologies used for the CALINE 4 simulation and PM2.5 mobile measurements. The results obtained are discussed in the next section. Fig. 4 shows the variations of PM2.5 for varying heights of the receptors for two sample model runs. For all the 135 scenarios, the vertical variations in the modelled PM2.5 concentrations are presented in Fig. S1(a) through S1(e) in the supplementary section. These figures are grouped based on the category of traffic composition. Results indicate that the PM2.5 concentrations decreased as the height of the receptor increased for all the runs. The difference in PM2.5 concentration between receptors at 0.1 m and 1.8 m ranged from 1.3–8.3 µg m–3. The lowest difference was observed when the wind speed was high with low traffic volume in category II vehicle composition, and the highest difference was reported for low wind speed and high traffic volume in category IV composition. Nevertheless, the results made it clear that pedestrians with shorter heights are exposed to a higher concentration of PM2.5 near busy roadways. Once this was established, G values were estimated for the PM2.5 concentration difference across height with varying traffic volume, traffic composition, wind speed, and ambient PM2.5 concentrations (as discussed in the previous section). Table 2 summarizes the effect of these variables on the PM2.5 concentration difference across height based on the absolute numerical value of G (which signifies the slope of PM2.5 concentration profile, assuming it to be linear). From Table 2, the wind speed, traffic volume, and traffic composition emerged as the influencing variables determining vertical differences in pedestrian’s exposure to PM2.5. Under traffic composition, car-dominated traffic with a higher proportion of HCVs increased the vertical difference in exposure. As the mode share of two-wheelers increased, the difference in exposure was found to reduce. For wind speed and traffic volume, lower wind speed and higher traffic volume increased the vertical difference in exposure. To further quantify their effect, additional CALINE 4 simulated runs were performed. In these runs, the value of the variable of interest was increased sequentially while keeping other variables constant. Subsequently, the G was calculated for each changing value of the variable of interest and analyzed. It was observed that for every increase in vehicular volume by 100 vehicles hr–1, the PM2.5 exposure difference increased by 0.13 µg m–3 m–1 in the range of pedestrian’s height (Fig. S2 in the supplementary section). For wind speed, calculations suggested that for every 1 m s–1 increase in wind speed, the PM2.5 exposure difference reduced by 0.095 µg m–3 m–1 in the range of pedestrian’s height (Fig. S3 in the supplementary section). The above results suggest that PM2.5 concentration exposure for short pedestrians is higher compared to tall pedestrians. Moreover, a region characterized by low wind speeds, or high traffic volume, or more HCVs in traffic, or a combination of any of these conditions would tend to increase this exposure difference. The results of the field study verifying the simulation results are discussed next. The first set of co-location experiments was conducted to evaluate the performance of sensors used (SPS30 and Panasonic PM2.5) relative to the reference instrument (GRIMM PAS 1.109). Results obtained for the indoor co-locations are shown in Figs. S4 and S5 in the supplementary section and the outdoor co-location in Fig. S6. From the figures, it can be observed that the performance of both the sensors relative to the state-of-the-art-reference instrument is comparable. To corroborate this, the Pearson correlation coefficient (r) was calculated. For SPS30, the value of r was 0.975, and for Panasonic PM2.5, the r came to be 0.972. These values met the U.S. EPA’s requirements for performance comparison between a test and a reference instrument. In addition, the p-value for the t-test at 95% confidence for both the sensors’ output was obtained as 0.78 for SPS30 and 0.74 for Panasonic PM2.5. Therefore, statistically, also no significant difference was observed between the sensors’ output and the reference instrument’s output. The second set of co-location experiments were performed where the sensors were co-located against each other. As discussed before, this was done for both indoor and outdoor environments. Figs. S7 and S8 present the results obtained. The performance comparison plots indicate that the sensors’ output is comparable with one another under similar conditions. To quantify this, CV was calculated. The CV values for indoor co-location was 0.014, and for outdoor co-location was 0.025, which are well within limits prescribed by U.S. EPA (which is 0.1). Also, the p-value for the t-test at 95% confidence for both the sensors’ output came to be 0.55 for indoor co-location and 0.48 for outdoor co-location. This confirms a statistically insignificant disparity in outputs from both the sensors with respect to each other under identical conditions. Finally, the third set of co-location experiments were conducted before field data collection on both days. In these experiments, the sensors’ outputs were compared relative to the reference instrument and with respect to each other when kept at the same height at the field measurement site. The results of these co-location experiments are summarized in Table S1. It can be seen that the CV values of intra-sensor comparison were within the prescribed limits of U.S. EPA during all the experiments. The t-tests also suggested insignificant differences in their outputs. When evaluated against the reference instrument, both the SPS30 and the Panasonic PM2.5 sensors’ outputs were deemed comparable. Furthermore, the CV and the p-values of the t-tests at the measurement site indicate that the outputs of PM2.5 from both the sensors, when held at the same height, did not differ significantly. Therefore, from all the co-location experiments conducted, it was confirmed that both the sensors used in the study performed identically at the same height from the ground level, and the PM2.5 outputs of the sensors were comparable to the values given by the reference instrument. The ambient meteorological data downloaded from the nearby monitoring station, ambient PM2.5 data and the PSL dataset during the hours of data collection are summarized in Table 3. Data averaging period from the source was chosen such that it included the time of the experiment. The CALINE 4 simulation results suggested that wind speed, traffic volume, and traffic composition influenced the vertical differences in PM2.5 concentrations near roadways. As the same site was used for the data collection on both days, the traffic mode share is expected to remain more or less the same. For wind speed, Day 1 was marked with lower wind speed compared to that in Day 2 (Table 3). On Day 1, the data was collected during the morning office-time peak hour, while on Day 2, the data was collected during the afternoon off-peak period. Hence, Day 1 was characterized by higher traffic volume compared to Day 2. However, the numerical value of the vehicular volume is not available due to the lack of instrumentation at the site. Fig. 5 compares the PM2.5 concentrations recorded at 80 cm and 150 cm while walking at the site during experiments for both the days (the time series of PM2.5 concentrations while walking at the site during the experiments for both the days is shown in Fig. 6). The PM2.5 concentration at 80 cm was observed to be consistently higher than the concentration recorded at 150 cm for both days. For the first day, the mean PM2.5 concentration at 80 cm was 56.68 µg m–3 (std dev: 6.02 µg m–3) and at 150 cm was 45.59 µg m–3 (std dev: 5.85 µg m–3), and on the second day, the mean PM2.5 concentration at 80 cm was 26.33 µg m–3 (std dev: 2.40 µg m–3) and at 150 cm was 21.24 µg m–3 (std dev: 1.92 µg m–3). The results were tested statistically using one-tailed paired t-tests with a null hypothesis as no difference in readings at 80 cm and 150 cm, and an alternative hypothesis as PM2.5 levels at 80 cm is greater than that observed at 150 cm. The p-value for the data collected on the first day was 2.12 × 10–12 and was 1.88 × 10-21 for the second day. Such lower p-values strongly indicate rejecting the null hypothesis, accepting the alternative one at a confidence of 95%. Therefore, statistically strong evidence exists that levels of PM2.5 observed at 80 cm height are higher than the levels observed at 150 cm on both days. In addition, it was observed that the difference in PM2.5 concentrations at 80 cm and 150 cm was higher on Day 1 compared to Day 2. As previously stated, Day 1 was marked with a higher traffic volume and lower wind speed. The results from CALINE 4 simulations suggested that such a combination enhances the PM2.5 difference across heights, which was also observed for mobile measurements. Overall, the current study’s results suggest that PM2.5 exposure levels are reduced with increasing heights of pedestrians. It was also observed that with increasing traffic volume, or decreasing wind speed, or increasing mode share of HCVs, the difference in exposure increased. CALINE 4 based results showed that for every 100 vehicles hr–1 increase in traffic volume, the PM2.5 exposure difference increased by 0.13 µg m–3 m–1 in the range of pedestrian’s height. For wind speed, calculations suggested that for every 1m s–1 increase in wind speed, the PM2.5 exposure difference was reduced by 0.095 µg m–3 m–1 in the range of pedestrian’s height. The current study examined how PM2.5 concentrations change with varying heights of pedestrians near roadways. CALINE 4 was used to simulate a variety of different scenarios involving vehicle volume, traffic composition, wind speed, and ambient PM2.5 concentrations to explore the gradient in PM2.5 concentrations with height. On-site mobile measurements supplemented the CALINE 4 observations. These observations showed that the PM2.5 concentration decreased with increasing heights of pedestrians. Furthermore, it was found that the difference in exposure across the heights of pedestrians is influenced by traffic volume, wind speed, and traffic composition. However, the on-site PM2.5 measurements were performed using low-cost particle sensors. Although low-cost sensors have recently been increasingly popular for personal evaluation and urban monitoring studies, their accuracy has always been a concern. Hence, the present study evaluated the performance of these sensors against a laboratory-grade optical particle counter (GRIMM PAS 1.109) in both indoor and outdoor conditions. The low-cost sensors were found to agree well with each other and GRIMM OPC in both indoor and outdoor conditions. Despite this, due to limited field data, the present study did not comment on the quantitative differences in PM2.5 values obtained from the on-site measurement experiments but was restricted to relative variations. The study primarily aims to understand the effect of pedestrians’ height on their exposure level near the roadway at varying conditions of vehicle volume, traffic composition, wind speed, and ambient PM2.5 concentrations, and flags height of pedestrians as an influential variable under changing conditions of vehicle volume, traffic composition, and wind speed. Mobile measurements were used to verify the simulated CALINE 4 observation of decreasing PM2.5 concentrations for a taller pedestrian relative to a shorter pedestrian. However, one of the study’s shortcomings is that the CALINE 4 do not account for the non-exhaust fraction of traffic emissions. According to Conte et al. (2019), non-exhaust traffic emissions account for a sizable portion of total traffic-related emissions, particularly in the coarse mode. Being coarse mode particles, they would thus tend to settle down (Patra et al., 2021b). As a result, it is likely that the non-exhaust fraction of traffic emissions will contribute to further increasing particle concentrations at low levels. This could be one of the reasons for the disparity between simulation and field observations (Fig. 6 and Fig. S1(a–e)). Therefore, to gain a more quantitative understanding of exposure differences, future research is needed to confirm the study's findings by conducting controlled experiments over a longer period using laboratory-grade PM instruments to quantify the differences in PM2.5 concentrations with varying pedestrian heights. The authors would like to thank Dr. Sachin S. Gunthe, EWRE division, IIT Madras and Dr. Gitakrishnan Ramadurai, Transportation division, IIT Madras for providing required instruments to carry out this study. The first author would also like to thank Dr. Brandon E. Boor, Purdue University, for introducing him to low-cost PM sensors. The authors declare that they do not have any conflicts of interest.1 INTRODUCTION
2 METHODS
2.1 CALINE 4 Simulations
2.1.1 Model formulation
Fig. 1. (a) Top View, (b) Side View of the link geometry used in the CALINE 4 model.
2.2 Mobile Measurements
2.2.1 Instruments
2.2.2 Sensor co-location
2.2.3 Data collection
Fig. 2. Data collection site for mobile PM2.5 measurements.Fig. 3. Position of both the sensors (SPS30 and Panasonic PM2.5) as carried by the volunteer for mobile PM2.5 measurements on the pedestrian pathway.
3 RESULTS AND DISCUSSION
3.1 CALINE 4 Simulation ResultsFig. 4. Vertical variations in PM2.5 when ambient PM2.5 levels are low, wind speed is medium, traffic volume is high and traffic composition is Category I (left), and ambient PM2.5 levels are high, wind speed is low, traffic volume is medium and traffic composition is Category III (right).
3.2 Field Measurement Results
3.2.1 Sensor co-location results
3.2.2 Field data collection resultsFig. 5. Comparison of PM2.5 concentration recorded at 80 cm and 150 cm while walking at the site during experiments for both the days.
Fig. 6. Comparison of PM2.5 concentrations recorded at 80 cm and 150 cm while walking at the site during experiments: (top) during peak traffic hours; (bottom) during off peak hours.
4 CONCLUSIONS
ACKNOWLEDGMENTS
DISCLAIMER
REFERENCES