Jordi F.P. Cornette 1, Thibault Coppieters1, Dominique Desagher2, Jurgen Annendijck2, Hélène Lepaumier2, Nathalie Faniel2, Igor Dyakov3, Julien Blondeau1, Svend Bram1

Thermo and Fluid Dynamics (FLOW), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium
Laborelec, ENGIE, 1630 Linkebeek, Belgium
Cellule Emissions Atmosphériques, Institut Scientifique de Service Public (ISSeP), 4000 Liège, Belgium


Received: October 1, 2019
Revised: December 23, 2019
Accepted: January 4, 2020
Download Citation: ||https://doi.org/10.4209/aaqr.2019.10.0487  


Cite this article:

Cornette, J.F., Coppieters, T., Desagher, D., Annendijck, J., Lepaumier, H., Faniel, N., Dyakov, I., Blondeau, J. and Bram, S. (2020). Influence of the Dilution System and Electrical Low Pressure Impactor Performance on Particulate Emission Measurements from a Medium-scale Biomass Boiler. Aerosol Air Qual. Res. 20: 499-519. https://doi.org/10.4209/aaqr.2019.10.0487


HIGHLIGHTS

  • Particles are prematurely measured when impactor is not overloaded.
  • Impactor overloading will change cut-off diameter of impactor.
  • Total particle number and mass are not influenced by dilution ratio.
  • Accumulation peak shifts towards larger particle with decreasing boiler load.
  • Total particle concentration is 4 times higher when impactor is not greased.
 

ABSTRACT

The accurate monitoring of particulate emissions from medium-scale, decentralized biomass combustion units is a major challenge for the deployment of this technology in the frame of the current energy transition. More specifically, the experimental characterization of the size of the emitted particles, i.e. using impactors, is still subject to discussions about the impact of the methodology on the measurement results. To meet with these challenges, particulate emissions from a medium-scale biomass boiler (4.5 MWth) were measured with Electrical Low Pressure Impactors (ELPI+) using two different dilution systems to examine the effect of dilution and performance of the ELPI+. For both the two stage dilution systems and one stage dilution system, no statistically significant correlation was found between the dilution ratio (DR) and particle total number concentration Ntot or between DR and mass concentration mtot. However, with both dilution system, a significant positive correlation was observed between DR and particles with diameter Dp < 0.01 µm due to measurement artefacts. With the one stage dilution system dilution systems, condensation appears to be promoted with reduced DR. When the ELPI+ impactor is not overloaded, the number concentration of fractions N< 0.01 and N0.01-0.1 reduce over time due to prematurely measuring particles. When the impactor is overloaded, N< 0.01 is overestimated and N0.01-0.1 and N0.1-1 are underestimated due to a change in cut-off diameter.


Keywords: Particulate matter; Biomass combustion; Dilution; ELPI+; Aerosol sampling.


INTRODUCTION


Biomass has been used for centuries around the world for generating energy due to its availability. More recently, biomass is gaining popularity due to being a viable alternative for fossil fuel but with a short-term carbon cycle, thus helping to reduce global warming (McKendry, 2002). Biomass combustion will not only avoid additional CO2 emissions, but medium-scale biomass combustion for district heating is often economically viable (Soltero et al., 2018). Biomass will be among the most important energy sources of the future (Dhillon and von Wuehlisch, 2013). 

A disadvantage of biomass combustion (in particular with solid fuels), beside NOx emission, is the emission of particles which have a known adverse effect on human health (Dockery et al., 1993; Kim et al., 2018). The health effects of inhalable particulate matter (PM) are respiratory and cardiovascular morbidity, such as aggravation of asthma, respiratory symptoms and an increase in hospital admissions; and mortality from cardiovascular and respiratory diseases and from lung cancer (WHO, 2013). Although PM is often expressed as mass concentration, research has shown that when exposed to the same mass concentration but with a different particle size, the smaller particles cause a greater adverse effect (Oberdörster et al., 1994) and thus, the particle size and particle concentration (or combined as the particle number size distribution) may be more appropriate to quantify PM. When investigating the toxicity of inhalable nanoparticles, particle surface area can be expected to be the most relevant metric to quantify PM (Schmid and Stoeger, 2016).

PM resulting from biomass combustion can be divided into organic and inorganic pollutants. Organic PM consists of products from incomplete combustion (PIC) and can be reduced by improving the combustion efficiency, while inorganic PM is mainly derived from ash constituents in the biomass (Nussbaumer, 2003). Various factors such as combustion conditions, type of biomass and combustion appliance have an effect on the particulate emission (McDonald et al., 2000). In medium- and large-scale boilers, organic PM contributes only a few percentages to PM1 although when the combustion conditions deteriorate, the organic fraction can become more dominant (Wierzbicka et al., 2005). Due to boiler design and combustion conditions the total polycyclic aromatic hydrocarbon (PAH) concentrations may vary over almost three orders of magnitude (Lillieblad et al., 2004). Depending on the combustion conditions and the type of combustion appliance, the particulate emissions from small-scale combustion appliances, expressed as mass concentration may vary up to a factor of 350 (Amaral et al., 2016) while the particle number concentration can vary in the range of 107–1010 particles cm–3 (Johansson et al., 2003). For medium- and large-scale installations, the particulate emissions emitted into the atmosphere mainly depend on the used particle removal technology such as fabric filters and electrostatic precipitators. However, the collection efficiency of these technologies are dependent on the particle size (Strand et al., 2002; Hasler and Nussbaumer, 1999).

An aerosol may contain up to three modes of particles: A nuclei mode (0.005–0.1 µm), an accumulation mode (0.1–2 µm) and a coarse mode (> 2 µm) (Whitby, 1978; John, 2011). With medium-scale biomass boilers, the fine mode (i.e., particles smaller than the coarse mode) is usually dominant over the coarse mode in both total number concentration and total mass concentration (Wierzbicka et al., 2005). During combustion of woody fuels in medium-scale boilers, the dominant elements in the coarse mode are Ca, K and S (Pagels et al., 2003; Wierzbicka et al., 2005) but also Mg, Si and Al are present (Jöller et al., 2005). The primary particles in the coarse mode mainly consist of compounds with low volatility such as CaO or SiO2 but the mode also contains the unevaporated part of volatile compounds such as compounds of K and S (Jöller et al., 2005). The composition of the fine mode depends on the fuel composition due to the different formation pathway, as explained by Jöller et al. (2005): For wood chips, the fine mode consists of mainly K, S and Cl gaseous compounds which undergo nucleation (due to the lack of seed particles) and subsequent condensation on particle surfaces. For bark, a considerable amount of fine Ca-rich particles, which act as seed particles for the condensation of alkali sulfates and chlorides, are released during combustion along with K, S and Cl. These Ca-rich particles may act as seeds for condensation and therefore the nucleation rates of new particles might be decreased. For waste wood, the main elements in the fine mode are Na, K, Cl, S, Zn and Pb. Zn is expected to evaporate to subsequently form ZnO, which nucleates and forms the seed particles for all further condensable species. Nucleation of other elements seems to be suppressed by surface condensation on these ZnO particles. Christensen and Livbjerg (1996) found that in the case of straw combustion, the fine mode mainly consists of KCl and K2SO4 (formed by homogeneous nucleation) and minor amounts of P while the elements Ca, Mg and Si were detected in the coarse mode. If the amount of K in the flue gas exceed the sum of Cl and S, the excess K exists as gaseous KOH which might condense as either K2CO3 or KOH (Christensen and Livbjerg, 1996). This is usually not the case with straw combustion but this can occur during woody biomass combustion (Christensen and Livbjerg, 1996; Valmari et al., 1998).

Aerosols are unstable by nature and are therefore challenging to measure unequivocally. Changes in size or composition of particles involve heat and mass transfer between the particles and with the surrounding gas, for example by condensation, evaporation, nucleation, adsorption, absorption, coagulation and chemical reaction. Chemical reactions within a particle, between particles and with the surrounding gas may be non-growth processes that change the composition or density of the aerosol particle but with little or no change in particle size (Hinds, 2011).

To obtain a representative measurement of an aerosol, the sampling system that collects the sample must be designed to maximize the quenching of aerosol chemistry and dynamics (nucleation, coagulation and condensation) in order to minimize modification of the aerosol size distribution in the sampling system (Biswas and Thimsen, 2011). This can be performed by diluting the flue gas sample with particle- and oil-free dry instrument air before characterizing the particulate emissions. Dilution of the sample reduces the particle concentration and flue gas temperature in order to stop chemical reactions in the gas flow and prevents further variation of the particle size in the sampling system, thus providing a more realistic and representative sampling of PM emissions (Amaral et al., 2015). Furthermore, most instruments that measure particle concentrations require dilution to obtain a sample that is within the measuring range of the measuring device. In addition, dilution prevents the condensation of water when the flue gases are cooled. However, research on internal combustion engines has shown that the physical and chemical properties of exhaust aerosols continuously change after their formation and one may significantly modify the aerosol properties by controlling this dilution process and thereby affecting the measurement (Giechaskiel et al., 2014). The particle size and concentration of volatile material emitted by diesel engines are strongly dependent upon dilution and sampling conditions, because sulfur and organic compounds are generally in the vapor phase in the tailpipe, and undergo a gas-to-particle conversion during dilution and cooling (Kittelson et al., 2006). The optimum dilution system for an aerosol depends strongly on the focus of the measurement (Lyyränen et al., 2004). The aim may be to simulate the dilution effect when the flue gas enters the atmosphere (i.e., atmospheric dilution) or the aim may be to preserve the number size distributions as unbiased as possible from the measurement and dilution setup artefacts and to produce a so-called ‘real’ size distribution of the particles as observed inside the chimney (Lyyränen et al., 2004). With atmospheric dilution, also the formation of secondary organic aerosol (SOA) due to photochemical oxidation of volatile organic compounds (VOCs) need to be accounted for since these emissions can cause the total organic aerosol concentration to increase by a factor of 1.5–2.8 (Grieshop et al., 2009).

In this study, the particle number size distribution of a medium-scale biomass boiler was measured using two Electrical Low Pressure Impactors (ELPI+) simultaneously with each a different compact partial flow dilution system: a porous tube diluter in combination with an ejector diluter (PTD + ED) and a Dekati axial diluter (DAD 100). The first objective is to evaluate the effect of the dilution system on the particle number size distribution. Both dilution systems have a heated dilution stage where the vapor pressure is reduced and thus the gas-to-particle transitions should be minimized which should lead to a representative particle number size distribution of the particulate emissions in the chimney. The second objective is to study the performance of the ELPI+ under different particle loads and under different boiler configurations.


METHODS



Plant Description

Parallel measurements were carried out at a 4.5 MWth biomass grate boiler that provides district heating to a nearby residential area. Downstream of the boiler, the plant is equipped with a multi-cyclone, a baghouse filter and a 0.83 MWth flue gas condenser (FGC), with the possibility to bypass the baghouse filters and the FGC separately. A schematic overview of the plant is given in the supplementary material Fig. S1. The influence of the FGC on the emissions was not the focus of this study and was therefore bypassed during the entire measuring period. The sampling probes for extracting the flue gas samples were located between the baghouse filters and the FGC. The flue gas temperature was around 150°C. The boiler was fueled with wood chips with a water content of about 45–50% (based on wet mass) originating from forests within an area of 100 km.


Sampling Systems

The sampling setup is shown in Fig. 1. Two Dekati Electrical Low Pressure Impactors (ELPI+) systems were used in parallel, both with a different compact partial flow dilution system, to measure the particle number size distribution of particles with a diameter between 6 nm and 10 µm, divided in 14 size fractions. The operating principle of the ELPI+ is based on the electric charging of the particles using a corona charger, after which the particles are classified in a cascade of inertial impactors that can detect the particle’s electrical charge. A more thorough description of the ELPI+ and its performance is given by Järvinen et al. (2014). A third sampling port was used to analyze the gaseous compounds in the flue gas. Air was used as a dilution gas to reduce particle and gas concentrations and to lower the temperature of the flue gas sample before entering the ELPI+. The dilution air originated from compressed air from the plant that underwent an air treatment to make it particle- and oil-free dry air. Each dilution system had its own air treatment unit.

Fig. 1. Sampling setup for the PTD + ED dilution system, the DAD 100 dilution system and the flue gas analyzers. Fig. 1. Sampling setup for the PTD + ED dilution system, the DAD 100 dilution system and the flue gas analyzers.

In both dilution systems the loss of particles is estimated to be low. Diffusional deposition is minimized in both dilution systems because the dilution air is introduced as a layer around the flue gas samples. Both gravitational settling and inertial depositions are considered to be of minor importance since no coarse fraction is present in the flue gas after the multi-cyclone and theses loses reduce with reducing particle diameter (Brockmann, 2011). Thermophoretic deposition is low since both dilution systems use heated air meaning that the deposition is reduced due to the lowered temperature gradient. Although, there is a difference between the temperature used in the two dilution systems.

In order to improve the particle collection efficiencies of the ELPI+ impactors, grease was applied on the aluminum collection substrates (Dzubay et al., 1976; Dunbar et al., 2005; Kuuluvainen et al., 2017). Not greasing the substrates results in a larger bouncing effect of impacted particles from a higher impactor stage to a lower stage which leads to an underestimation of the number of particles in the correct size fraction and an overestimation of the number of particles in a smaller size fraction (Virtanen et al., 2010; Chen et al., 2011). Greased substrates initially have a good collection efficiency but this decreases with particle load in the impactor (Turner and Hering, 1987; Tsai and Cheng, 1995). On the other hand, with ungreased substrates, the particle load on the substrates changes the surface characteristics causing the collection efficiency to increase over time (Tsai and Cheng, 1995). With ELPI+ A the grease was dissolved in acetone and then applied with a brush on the substrates while with ELPI+ B the grease was applied as an aerosol using a spray can. When grease is applied with a brush, it is a thicker layer than when it is applied with a spray can. A thicker grease layer greatly improves the particle collection efficiency (Pak et al., 1992). A sample with a higher relative humidity will also increase the collection efficiency (Chen et al., 2011).

The porous tube diluter + ejector diluter system (PTD + ED) is a two-stage dilution system manufactured by Venacontra (Fig. S2) and was connected to ELPI+ A. The purpose of the two-stage system is to keep the particle size distribution unchanged by first diluting the flue gas sample at the same temperature to lower the vapor pressure, and then decreasing the temperature by diluting at ambient temperature. In the first stage, the flue gas sample is introduced by a heated probe (at 150°C) in the PTD where it is mixed with heated (150°C) dilution air to lower the partial pressure while preserving the temperature. The heated air creates an unfavorable environment for nucleation (Lyyranen et al., 2004) and condensation of semi-volatile organic compounds will be prevented (Fachinger et al., 2017). The PTD is a coaxial cylindrical diluter where the dilution air flows through a porous inner tube, thus creating a layer of clean air around the aerosol sample (Auvinen et al., 2000; Lyyranen et al., 2004). The flow velocity of the dilution air through the pores is greater than the deposition velocity of the particles, thus the particles will not deposit in the PTD (Auvinen et al., 2000). In addition, the use of heated dilution air will prevent particles from depositing due to thermophoresis. In the second stage, the flue gas sample is mixed in the ED with dilution air at ambient temperature in order to further dilute the sample and to reduce the temperature before entering the ELPI+. The ED ensures good mixing and rapid entrainment because the flue gas sample enters the mixing chamber through a venturi with a high velocity (Lyyranen et al., 2004). The PTD + ED dilution system is widely used to sample particulate emissions from biomass combustion (Tissari et al., 2007, 2008b; Lamberg et al., 2011; Kaivosoja et al., 2013; Grigonyte et al., 2014; Torvela et al., 2014; Dyakov et al., 2016). The calculation of the dilution ratio (DR) is based on the dry CO2 concentration before and after dilution corrected for the background CO2 (Grigonyte et al., 2014).

The Dekati axial diluter system (DAD 100) is a single-stage dilution system (Fig. S3) and was connected to ELPI+ B. In the DAD 100, heated (60°C) dilution air is introduced as a layer around the flue gas sample resulting in low particle losses, as claimed by the manufacturer (Dekati, 2010). The DAD 100 was used in previous research to dilute flue gases from coal combustion (Mertens et al., 2014, 2015). The DR is calculated with the volumetric flow rate of the dilution air and the diluted flue gas sample. Both calculation methods of DR (CO2 based and flow based) result in the same definition of DR, i.e., ratio of the final flow to the initial flow. No dilution corresponds with a dilution ratio of one.

Three different gas analyzers were used to analyze the gaseous compounds of the flue gas. A Fourier-transform infrared spectroscopy (FTIR) analyzer was used to monitor the concentration of water vapor, carbon dioxide, carbon monoxide, nitrogen monoxide, nitrogen dioxide, nitrous oxide, sulfur dioxide, hydrogen chloride, hydrogen fluoride, ammonia and organic gaseous compounds (OGCs). The FTIR was equipped with a zirconium dioxide (ZrO2) sensor to measure the oxygen concentration. A flame ionization detector (FID) was used to measure the total organic carbon (TOC) and was calibrated with propane. The flue gas was sampled at 180°C and was kept constant throughout the FTIR, the FID and the sampling lines in between, to allow the analysis of the hot and wet flue gas (and of the less volatile organic compounds in it) and to prevent condensation thus avoiding loss of water soluble components. A second outlet of the FTIR was connected with a gas cooler in order to dry and cool the sample after which the third gas analyzer, a Horiba PG-250, measured the dry oxygen, carbon dioxide, carbon monoxide, nitrogen oxide and sulfur dioxide concentrations. The Horiba was calibrated with the appropriate zero and span gases.


Measurement Plan

The emissions of combustion were studied with multiple tests at three different operation modes of the plant: boiler at high load (i.e., 100%), boiler at low load (i.e., 50%) and boiler at high load with bypass of the baghouse filters, denoted by respectively HL, LL and HL BB. The measurements were carried out with both ELPI+’s and then the measured concentrations were compared with each other. ELPI+ A is therefore the reference for ELPI+ B and vice versa. Using another measuring device as a reference, such as a Scanning Mobility Particle Sizer (SMPS), is not as straightforward because the aerodynamic diameter and mobility diameter can be extremely different (van Gulijk et al., 2004). The tests were carried out on two consecutive days, namely S1 and S2. During the first day, the boiler was operated continuously at high load, which allowed us to compare the ELPI+’s, compare the dilution setups and study the influence of DR. The second day the boiler was operated first at high load, then with bypass of the baghouse, then at low load and finally back to high load. These tests allowed us to investigate the importance of greasing the ELPI+ substrates, the influence of the boiler operation mode and the influence of overloading the ELPI+ impactor. Due to the high number of particles in the flue gas during the bypass of the baghouse, both ELPI+ impactors were overloaded. The user manual of the ELPI+ states that a total of 1 mg of particles collected per impactor stage can be considered as an absolute maximum although this value can depend on the particle distribution and the particle properties (Dekati, 2016). After the baghouse bypass tests, a clean impactor was inserted in ELPI+ B while with ELPI+ A the overloaded impactor was retained for the remaining tests. This allowed for comparing the influence of overloading the ELPI+. Garra et al. (2016) concluded that long-term collection with the original ELPI biased the particle size distribution by measuring more particles in Stages 6–8 and less particles in Stages 3–5. The authors explained the biasing by the change in jet-to-impaction distance due to the formation of domes of accumulated particles on the impactor which changes the cut-off diameter of the impactor. Because the ELPI+ contains an additional impactor stage and an electrical filter stage (Järvinen et al., 2014), this would correspond with more particles expected in Stages 8–10 and less in Stages 5–7 as a bias from long-term collection with the ELPI+. Impactors have been designed and developed that can reduce and even eliminate the effects of particle overloading (Tsai and Cheng, 1995; Peters et al., 2001; Tsai et al., 2012; Chien et al., 2015; Le and Tsai, 2017; Le et al., 2019), but these are not suitable for implementation in the ELPI+. It should however be noted that the effects of overloading the ELPI+ impactor can be largely postponed by using oil-soaked sintered impactor plates instead of greased impactor plates (van Gulijk et al., 2003).

The ELPI+ measures in real time and therefore the ELPI+ results are time averaged values (± standard deviations) of each test. The average sampling duration for each ELPI+ test was 10 minutes with a minimum of 6 minutes and a maximum of 18 minutes. Tests shorter than 6 minutes are excluded from the analysis. As is the case with the ELPI+, the gas analyzers measure in real time and therefore the results are also time averaged values (± standard deviations) of each test.

The average particle density ρ is an input parameter of the ELPI+ and has to be estimated, although the chemical compositions of different size fractions may induce a significant change in density per particle size (Coudray et al., 2009). Nonetheless, since the particulate emissions are dominated by the fine particles, the average particle density from wood combustion was estimated at 2.0 g cm–3 as assumed by Pagels et al. (2002) and Lillieblad et al. (2004) and as concluded by Coudray et al. (2009). With both dilution systems, isokinetic sampling was not necessary because the flue gas is dominated by fine particles, as almost all coarse particles are trapped by the multi-cyclone and thus the particles follow the gas streamlines (Hinds, 1999).


RESULTS AND DISCUSSION


The PM emissions are characterized by their particle number size distribution which can be summarized by the quantities total number of particles Ntot and geometric mean particle diameter (GMD). The dilution settings of the different tests and Ntot and GMD are represented in Table 1. The displayed ELPI+ results are corrected for their dilution. Some data were rejected from the analysis due to incorrect or incomplete measuring with the ELPI+ (see notes in Table 1).

Table 1. Sampling conditions and particulate emissions (± standard deviation) from measurements.

The two dilution systems are complementary since the DAD 100 operates with a DR between 4 and 10 while the PTD + ED operates with a DR between 10 and 51. With the PTD + ED the DR is calculated as a time averaged value (± standard deviation) from continuous CO2 measurements. With the DAD 100 the DR was set to a specific value and was not measured continuously and so there is no standard deviation. The individual DR for PTD and ED are estimated using the known volumetric flow rates, the value of DRtot and the formula DRtot = DRPTD × DRED. The residence time of the particles in the PTD and the ED were estimated in the ranges 0.3–0.5 s and 0.8–0.9 s, respectively. The residence time in the DAD 100 dilution system can not be estimated unequivocally as dilution takes place in the extension of the sampling line and thus the mixing chamber is not clearly defined.

The results of the gas analyzers for each test are shown in Table 2. All gas concentrations are dry based (except for H2O) and are corrected to a 13 vol% O2 concentration (except for H2O and O2) using the H2O and O2 concentrations measured with the FTIR. The Horiba gas analyzer was able to measure dry concentrations of O2, CO2, CO, NOx and SO2 but the SO2 concentration was below the detection limit (ppm level). The TOC values measured by the FID are expressed as C-equivalent mass per normal cubic meter dry gas, corrected to an O2 concentration of 13 vol%. The measured TOC concentrations are low (< 5 mg C Nm–3) and close to the estimated limit of quantification of the FID. Besides the compounds presented in Table 2, the FTIR was also able to monitor N2O, SO2, HCl, HF, NH3, CH4, acetaldehyde and formaldehyde, and publicly available spectra were used to detect formic acid and acetic acid but none of these components were detected above the detection limit (ppm level). The O2 measured with the FTIR appears to be slightly higher than the O2 concentration measured with the Horiba. This difference may be due to the fact that the FTIR results are obtained by measuring in the wet flue gas and then calculating the concentration on dry basis using the measured H2O concentration while the Horiba measures the concentration in the dried flue gas. Additionally, the difference may be due to the difference in O2 measuring method as the FTIR uses a zirconium cell while the Horiba uses a galvanic cell. These small differences cause some of the other gas concentrations to be slightly different. The CO2 concentration appears to be slightly higher with the Horiba. The CO concentration appears to be higher with the Horiba in the first tests and higher with the FTIR in the last tests but both show an increased concentration during low boiler operation and they have similar standard deviations. The NOx concentration is lower with the FTIR but both analyzers show a decreased concentration during low boiler operation which may be related to the lower temperature in the combustion chamber.

Table 2. Gas concentrations (± standard deviation) measured with FTIR, Horiba, FID gas analyzers. All concentrations are dry based (except for H2O) and are corrected to a 13 vol% O2 concentration (except for H2O and O2).


Time Series of Particle Concentrations

One of the main advantages of the ELPI+, in addition to its ability to measure a large range of particle sizes, is that it has a fast sampling rate (10 Hz). This allows for a continuous measurement of the particle number concentration in each impactor stage. In Fig. 2 the time series of particulate and gaseous emissions during the first measuring day are presented. In Fig. 2(a) the flue gas was diluted with the PTD + ED and in Fig. 2(b) the DAD 100 dilution system is used. The evolution in time of the total number of particles Ntot and the size fractions N0.1-1 (0.1 µm < Dp < 1 µm: Stages 5–9), N0.01-0.1 (0.01 µm < Dp < 0.1 µm: Stages 2–4) and N<0.01 (Dp < 0.01 µm: Stage 1) are presented. The size fraction N1-10 (1 µm < Dp < 10 µm: Stages 10–14) is not presented here since the amount of particles measured in this fraction is several orders of magnitude lower than in the smaller fractions. In Fig. 2(c) the gas concentrations in the flue gas measured by the FTIR are presented. The gas concentrates are dry based and corrected to 13 vol% O2. The gas concentrations indicate that the boiler operation during high load is quite stable over a large time scale. Over a smaller time scale, variations can be observed in most gas concentrations. These variations appear to correspond to the variations in particulate emissions.

Fig. 2. Time series of emissions during S1 with boiler operating at high load. (a) Particulate emissions when diluting with the PTD + ED dilution system. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2. Fig. 2. Time series of emissions during S1 with boiler operating at high load. (a) Particulate emissions when diluting with the PTD + ED dilution system. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.

The PTD + ED dilution system was connected to ELPI+ A and the DAD 100 dilution system was connected to ELPI+ B during all tests, except during Test S1.2. During Test S1.2, the ELPI+’s were interchanged to check whether they yield the same results with the same dilution system (i.e., the DAD 100 dilution system was connected to ELPI+ A and the PTD + ED dilution system was connected to ELPI+ B). All measurements performed with ELPI+ A are displayed as solid lines while all measurements performed with ELPI+ B are displayed as dashed lines. Seen from the PTD + ED dilution system point of view (Fig. 2(a)), there is a good agreement between the two ELPI+’s, although Ntot is slightly higher compared with the previous and next test. This is mainly the result of the higher amount of particle in fraction N0.01-0.1. Seen from the DAD 100 dilution system point of view (Fig. 2(b)), there is a relatively good agreement between the two ELPI+’s. Fraction N0.1-1 during S1.2 is similar to the other tests. Fraction N0.01-0.1 during S1.2 is situated between the previous and next test with which it follows the trend of the DAD 100 that this fraction decreases with time. Fraction N<0.01 with the DAD 100 during S1.2 appears to have two peaks which corresponds well with the peaks in Ntot of the PTD + ED although with the PTD + ED these peaks are visible in both N<0.01 and N0.01-0.1. Based on these observations, it can be concluded that both ELPI+’s yield the same results, although there is a relatively large variation between the measurements with the same ELPI+ over time. These variations over time are believed to be the result of the increasing effect of prematurely measuring the smallest particles, as argued by van Gulijk et al. (2001). The authors propose that this phenomenon occurs in three phases (van Gulijk et al., 2001): First, at very low particle load on the impactors, the impactor stages of the accumulation peak (ELPI+ Stage 5 and 6) are covered with a fluffy bed of particles, which acts as a filter for the smaller particles. Then, in a second phase, at slightly higher impactor load, piles of particles form on the impactor plates and thereby change the cut-off diameter. In a third phase, at high impactor load, the piles of particles have become so large that re-entrainment occurs and probably a mechanical equilibrium develops. Fraction N0.01-0.1 appears to reduce over time with both dilution systems although the gas concentrations do not suggest that the combustion conditions change. This suggests that the ELPI+ underestimates the amount of particles in Stages 2–4 with increasing time, even when the ELPI+ impactor is not overloaded. This can be explained by the phenomenon of prematurely measuring those particles. With the PTD + ED, Fraction N0.01-0.1 is slightly above Fraction N0.1-1 during the first two tests and is slightly below Fraction N0.1-1 during the last two tests. With the DAD 100 this trend is more pronounced as the used DR is lower and thus the particle load on the impactor of ELPI+ B is larger. During Test S1.1 with DAD 100, Fraction N<0.01 is 1.8 times higher and Fraction N0.01-0.1 is 4.8 times higher than during Test S1.3. Both fractions further reduce over time. Fraction N<0.01 also appears to have a positive correlation with DR, as will be discussed later on. Particle Fraction N0.1-1 appears to be similar and stable for both dilution systems and does not seem to be affected by DR.

In Fig. 3 the time series of particulate and gaseous emissions during Test S2.1 to S2.3 and S2.10 are presented. Mind the time gap between Tests S2.3 and S2.10 because the tests at different operation modes are discussed separately. During Test S2.1 with the PTD + ED (Fig. 3(a)) no grease was applied on the aluminum collector substrates of the ELPI+ impactor. Ntot and N<0.01 during this ‘no grease’ test are drawn relative to the grey scale since they are of a different order of magnitude due to the bouncing effect. In all other tests (including tests at other operation modes), grease was applied on the substrates. The purpose of this test is merely to demonstrate the importance of proper greasing and is therefore not included in the further analysis. With the ‘no grease’ test, the average Ntot was a factor of 4 higher and the average number of smallest particles, measured in the fraction N<0.01, was a factor of 10 higher compared with tests with the same dilution system when grease was applied. Fraction N0.01-0.1 during the ‘no grease’ test is mostly lower than Test S2.3 with the PTD + ED and Test S2.1 with the DAD 100 although the fraction reduces over time with all tests. The underestimation of the number of particles in the correct size fraction, due to the bouncing effect, is more difficult to observe because this is less pronounced. One particle not measured in the correct stage due to bounce is measured as multiple particles in a lower stage since the particle charging is size dependent. What makes the underestimation even more challenging to observe, is the variation of the size fractions over time. Ntot decreases from 1.3 × 107 particles cm–3 at the start of the test to 2.9 × 106 particles cm–3 at the end of the test, which is mainly the result of the decreasing of Fraction N<0.01. Also Fraction N0.01-0.1 appears to decrease over time, especially at the start of the test. On the other hand, Fraction N0.1-1 appears to increase over time at the start of the test. This is in accordance with what van Gulijk et al. (2001) observed: a decrease of particles with Dp between 0.03 and 0.1 µm and an increase of particles with Dp > 0.1 µm over time. This phenomenon of prematurely measuring small particles causes the opposite effect than the particle bounce: Instead of particles travelling too far there are particles that travel not far enough in the impactor (van Gulijk et al., 2001). The effect of prematurely measuring small particles can also be observed during Test S2.1 to S2.3 with the DAD 100 dilution system (Fig. 3(b)) as both the fractions N<0.01 and N0.01-0.1 decrease over time. This effect starts almost immediately at the start of measurement S2.1 (i.e., with a clean impactor) and increases over time. The underestimation of Fractions N<0.01 and N0.01-0.1 and overestimation of Fraction N0.1-1 due to the premature measuring of particles increase over time but become more stable after a while due to an equilibrium that develops in the impactor. With the DAD 100, an increase of the fraction N0.1-1 is however not observable. It is noted that during the measurements of Tests S2.2 and S2.3 with the DAD 100 dilution system an unstable pressure was observed in the ELPI+ which can be the reason for the fluctuations in Fraction N<0.01. For Tests S2.1–S2.3 and S2.10 with the DAD 100 and Test S2.3 with the PTD + ED fraction N0.1-1 appears to be similar for both dilution systems and similar to S1. Fraction N<0.01 with the PTD + ED dilution system during Test S2.3 is similar to the one of Test S1.4 which has almost the same DR, although during Test S2.3 an increasing trend can be observed. During Test S2.2 with the PTD + ED Fraction N<0.01 is higher as expected. Since this test is the first test with a clean impactor (with greased substrates), the effect of prematurely measuring particles is not yet so pronounced. However, a decreasing trend can not be observed due to the limited duration of the test. Test S2.10 with the PTD + ED was performed with an overloaded ELPI+ impactor. Both N0.01-0.1 and N0.1-1 appear to be underestimated compared with the DAD 100 and N<0.01 appears to be overestimated. The underestimation may be due to the change in cut-off diameter of the impactor stages and the overestimation may be the result of an increasing bouncing effect due to the saturated impactor plates. Note that, based on the gas concentrations, the boiler is still recovering from the low load operation mode and is not yet fully stable (Fig. 3(c)).

Fig. 3. Time series of emissions during S2.1 to S2.3 and S2.10 with boiler operating at high load. (a) Particulate emissions when diluting with the PTD + ED dilution system. Ntot and N<0.01 during Test S2.1 (i.e., no grease test) are drawn relative to the grey scale since they are of a different order of magnitude. The impactor of ELPI+ A was overloaded during Test S2.10. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.Fig. 3. Time series of emissions during S2.1 to S2.3 and S2.10 with boiler operating at high load. (a) Particulate emissions when diluting with the PTD + ED dilution system. Ntot and N<0.01 during Test S2.1 (i.e., no grease test) are drawn relative to the grey scale since they are of a different order of magnitude. The impactor of ELPI+ A was overloaded during Test S2.10. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.

In Fig. 4 the time series of particulate and gaseous emissions during Test S2.4 to S2.5b are presented. During these tests, the boiler was operated at high load with the baghouse filters bypassed. During this operation mode, Ntot is much higher and Fraction N0.1-1 is clearly more dominant, demonstrating the need for the installation of baghouse filters. The accumulative mass of particles collected per impactor stage during these tests exceeded the limit value of 1 mg given by the ELPI+ user manual (Dekati, 2016). With the PTD + ED during Test S2.4 Stages 6–8 and 13–14 got overloaded and by the end of Test S2.5b Stages 6–14 were overloaded. With the DAD 100 Stages 6–9 and 13–14 were overloaded by the end of Test S2.5a. With both dilution systems, Fractions N0.1-1 and N0.01-0.1 reduce over time. This is in accordance with overload test S2.10 with the PTD + ED, as the overload increases, the concentrations of Fractions N0.1-1 and N0.01-0.1 are increasingly underestimated. With the DAD 100 Fraction N<0.01 also reduces over time. However, with the PTD + ED Fraction N<0.01 does not appear to reduce over time but appears to correlate with DR.

Fig. 4. Time series of emissions during S2.4 to S2.5b with boiler operating at high load with the baghouse bypassed. (a) Particulate emissions when diluting with the PTD + ED dilution system. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.Fig. 4. Time series of emissions during S2.4 to S2.5b with boiler operating at high load with the baghouse bypassed. (a) Particulate emissions when diluting with the PTD + ED dilution system. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.

In Fig. 5 the time series of particulate and gaseous emissions during Test S2.6 to S2.9 are presented. During these tests, the boiler was operated at low load, which can be observed from the increased CO concentration and the reduced NOx concentration (Fig. 5(c)). Note that the combustion conditions are not fully stable as the CO concentration is still increasing and the NOx concentration is still decreasing during the first two tests. The impactor of ELPI+ A, connected to the PTD + ED dilution system, is still overloaded with particles due to the previous tests. A clean impactor with greased substrates was inserted in ELPI+ B. With the PTD + ED dilution system, N0.1-1 and N0.01-0.1 appear to reduce over time (Fig. 5(a)). Fractions N0.1-1 and N0.01-0.1 are believed to be more underestimated as the overloading increases because of a shift in cut-off diameter. Moreover, Fraction N<0.01 appears to correlate with DR. With the DAD 100 dilution system, Fraction N0.1-1 appears to be stable and Fractions N0.01-0.1 and N<0.01 appear to reduce over time during Test S2.8 and S2.9 (Fig. 5(b)).

Fig. 5. Time series of emissions during S2.6 to S2.9 with boiler operating at low load. (a) Particulate emissions when diluting with the PTD + ED dilution system. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.Fig. 5. Time series of emissions during S2.6 to S2.9 with boiler operating at low load. (a) Particulate emissions when diluting with the PTD + ED dilution system. (b) Particulate emissions when diluting with the DAD 100 dilution system. (c) Gaseous emissions measured with FTIR. Gas concentrations are dry based and corrected to 13 vol% O2.


 Particle Number Size Distributions

The PM emissions measured by the ELPI+ are expressed as time series of particle number concentrations for each impactor stage. When time averaging the particle concentration in each stage, an average particle number size distribution for each test can be obtained. This distribution represents the amount of particles measured within a size interval divided by the logarithmic range of the size interval (dN/d log Dp on vertical axis) at the geometric mean of each size interval (Dp on horizontal axis).

Before going deeper into the different operation modes, observations are made about the general shape of the distributions (Figs. 6–9). With both dilution systems and during all operation modes, an accumulation mode with a peak between 0.1 and 0.5 µm can be distinguished, which corresponds with previous research (Hueglin et al., 1997; Johansson et al., 2003; Pagels et al., 2003; Sippula et al., 2007; Tissari et al., 2008b; Lamberg et al., 2011; Krugly et al., 2014; Fachinger et al., 2017). With most of the tests, the smallest particles (Dp < 0.03 µm: Stages 1–2) suggest that also a second mode may be present, although this has to be interpreted with the necessary caution as the measuring range of the ELPI+ does not completely cover this mode. The observation of a nuclei mode in the particle number size distribution has been reported in literature regarding residential wood combustion (Hedberg et al., 2002; Krugly et al., 2014; Fachinger et al., 2017). However, with medium-scale boilers, the observation of a nuclei mode is rather unusual although it has been observed in some work as a weak mode around 40 nm (Pagels et al., 2003). Therefore, the relatively high number of the smallest particles (Dp < 0.03 µm) is probably the result of measuring artefacts and the result of the baghouse filters that have a lower collection efficiency for those particles, which both will be discussed later on.

In Figs. 6 and 7 the particle number size distributions at high load with each of the two dilution systems are shown at different dilution ratios. With the PTD + ED dilution system, eight tests are included while with the DAD 100 dilution system nine tests are included. During Test S1.2 (green distribution in both graphs), the ELPI+’s were interchanged (i.c.) to check whether they yield the same results with the same dilution system. Seen from the PTD + ED dilution system point of view (Fig. 6), there is a good agreement between the two ELPI+’s, except for Impactor Stage 2 (Dp = 0.021 µm) which shows a slightly higher amount of particles at Test S1.2. Seen from the DAD 100 dilution system point of view (Fig. 7), there is also a good agreement between the two ELPI+’s, but a wide spread between the measurements with the original ELPI+ B can be observed (especially for particles with a diameter Dp < 0.1 µm). These variations between the measurements of ELPI+ B are believed to be the result of the increasing effect of prematurely measuring the smallest particles. It can be concluded that both ELPI+’s yield the same results, given the relatively large variation between measurements with the same ELPI+ over time, which is in accordance with what was already determined when observing the time series. 

Fig. 6. Particle number size distributions at high load with the PTD + ED dilution system; i.c.: ELPI+ interchange, n.g.: no grease, o.l.: impactor overload. Fig. 6. Particle number size distributions at high load with the PTD + ED dilution system; i.c.: ELPI+ interchange, n.g.: no grease, o.l.: impactor overload.

With the PTD + ED dilution system (Fig. 6), it can be observed that during the ‘no grease’ (n.g.) test (i.e., S2.1) the particles measured in the ELPI+ filter stage (i.e., Stage 1) is clearly higher and the particles measured in Stages 3 and 4 is slightly lower which is due to the increased bounce effect: overestimation of small particles and underestimation of correct size. During the overload (o.l.) test (i.e., S2.10), the distribution clearly differs from the other tests. More particles can be observed in Stage 1 and less in Stages 2–6. The amount of particles in Fraction N0.01-0.1 is close to zero and the peak of the accumulation mode is halved. For the remaining high load tests with the PTD + ED dilution system, Ntot is between 1.1 × 106 and 1.6 × 106 particles cm–3 and GMD is between 27 nm and 40 nm. With four tests the peak of the accumulation mode is at Dp = 0.12 µm (Stage 5) and with two tests the peak is at Dp = 0.20 µm (Stage 6). The residence time during high load was estimated between 0.41 s and 0.48 s in the PTD and between 0.86 s and 0.89 s in the ED. It can be observed that an increase in DR leads to an increase of the smallest particles, measured in the ELPI+ Stage 1, although there is a wide spread between tests with the same DR.

With the DAD 100 dilution system (Fig. 7), an unstable pressure (u.p.) in the ELPI+ was observed during two tests (i.e., S2.2 and S2.3). During these tests, the amount of particles in Stage 1 appears to be lower compared to the other tests. For the remaining high load tests with the DAD 100, Ntot is between 3.9 × 105 and 1.4 × 106 particles cm–3 and GMD is between 33 nm and 133 nm. Notice the large spread between these quantities compared with the PTD + ED dilution system. The peak of the accumulation mode is at Dp = 0.12 µm (Stage 5) when DR = 10 but the peak shifts to the right (Dp = 0.20 µm: Stage 6) when the DR decreases. As with the PTD + ED dilution system, it can be observed that an increase in DR leads to an increase in the number of smallest particles, measured with the ELPI+ Stage 1, but there is an even wider spread between tests with the same DR. This wide spread between the amount of smallest particles in Stage 1 is the cause for the large spread between Ntot and GMD. 

Fig. 7. Particle number size distributions at high load with the DAD 100 dilution system; i.c.: ELPI+ interchange, u.p.: unstable ELPI+ pressure. Fig. 7. Particle number size distributions at high load with the DAD 100 dilution system; i.c.: ELPI+ interchange, u.p.: unstable ELPI+ pressure.

The particle number size distributions during low load are presented in Fig. 8. With the PTD + ED four tests are included and with the DAD 100 two tests are included. With the DAD 100 the ELPI+ impactor was not overloaded and it can be observed that the peak of the accumulation mode shifts from Stage 5 during high load (when DR = 10) to Stage 6 during low load. This is in accordance with what has been reported in literature: A shift of the peak towards the larger particle sizes with decreasing load (Johansson et al., 2003; Lillieblad et al., 2004; Tissari et al., 2008a; Torvela et al., 2014). With the PTD + ED the tests are performed with an overloaded ELPI+ impactor. More particles can be observed in Stage 1 and the amount of particles in Fraction N0.01-0.1 is close to zero, which is in accordance with the high load overload test (i.e., S2.10 in Fig. 6). However, during the low load overload tests, the peak of the accumulation mode is not halved (compared to the DAD 100 tests) but the peak is rather shifted from Stage 5 and 6 during high load to Stage 7 during low load. This shift can be both the result of the decreasing boiler load, as with the DAD 100, and the result of the impactor overloading (i.e., change in cut-off diameter of impactor stages). Note that with the PTD + ED the number of particles in Stages 1, 4, 5 and 6 decrease with decreasing DR, although this could also be a consequence of the increasing overloading as the lowering of DR is performed chronologically.

Fig. 8. Particle number size distributions at low load; o.l.: impactor overload. Fig. 8. Particle number size distributions at low load; o.l.: impactor overload.

The particle number size distributions at high load with bypass of the baghouse of four tests with the PTD + ED and two tests with the DAD 100 are shown in Fig. 9. The accumulation mode is more dominant during this operation mode, showing the need for installing baghouse filters. Due to the high number of particles, the impactors of both ELPI+’s were overloaded with particles, according to the ELPI+ user manual (Dekati, 2016). With both dilution systems, the peak of the accumulation mode decreases with increasing test number and thus the peak decreases as time goes on. With the PTD + ED the peak of the mode also shifts from Stage 6 to Stage 7 over time and the number of particles in Stage 7 increases over time which shows that the cut-off diameters change as the particle loading increases. With the DAD 100, Stages 2 and 3 are close to zero. As with all previous tests, an increase in DR seems to lead to an increase of the smallest particles. During this operation mode, the particle number concentrations measured in Stage 6 and 7 with both ELPI+’s are close to upper limit of the ELPI+ measuring range of these stages. An analogue discussion about the particle mass size distribution can be found in the supplementary material. 

Fig. 9. Particle number size distributions at high load with the baghouse bypassed; o.l.: impactor overload. Fig. 9. Particle number size distributions at high load with the baghouse bypassed; o.l.: impactor overload.


Comparison of Dilution Systems

The visual comparison of (a) total particle number, (b) total particle mass and (c) geometric mean diameter between the PTD + ED and the DAD 100 dilution system is shown in Fig. 10. The solid line indicates the 1:1 relation and the dashed lines mark the ± 30% interval. The points represent time averages of a test measured by both dilution systems simultaneously. These tests are: four tests at high load, the high load test with the ELPI+’s interchanged, the high load test with no grease used with ELPI+ A (connected to PTD + ED), the high load test with the impactor of ELPI+ A overloaded (connected to PTD + ED), two low load tests (with ELPI+ A overloaded) and two tests at high load with the baghouse bypassed (with both ELPI+’s overloaded). 

Fig. 10. The correlation of (a) total particle number Ntot, (b) total particle mass mtot and (c) geometric mean diameter GMD between the PTD + ED and DAD 100 dilution systems. Fig. 10. The correlation of (a) total particle number Ntot, (b) total particle mass mtot and (c) geometric mean diameter GMD between the PTD + ED and DAD 100 dilution systems.

When diluting with the PTD + ED dilution system, a higher Ntot is obtained during all tests, except with one high load test (Fig. 10(a)). When diluting with the PTD + ED dilution system, a higher mtot is obtained during all tests, except with the ELPI+ interchange test and the high load overload test (Fig. 10(b)). Thus, with exclusion of the overload test, there is always more particulate mass collected with ELPI+ A. This could be the result of the thicker layer of grease applied on the substrates of ELPI+ A that improves the particle collection efficiency. The GMD with the PTD + ED dilution system is lower than with the DAD 100 dilution system for all tests except one high load test (Fig. 10(c)). This exception is the same test as the exception in Ntot, namely Test S1.1.



Influence of Dilution Conditions on Particulate Measurements

The influence of dilution on the number of particles, the mass of particles and the particle diameter is assessed using the Spearman correlation coefficient rs. The correlations between DR and (i) number of particles N per size fraction, (ii) mass of particles m per size fraction, (iii) each stage separately and (iv) GMD are shown in Table 3. Four types of configurations had a sufficient amount of tests to perform the analysis: PTD + ED high load (n = 6), DAD 100 high load (n = 7), PTD + ED low load (n = 4) and PTD + ED high load with baghouse bypass (n = 4). One and two asterisks indicate significance at a 0.05 and 0.01 probability level, respectively. Note that no distinction is made between number N and mass m for the separated stages because the conversion from number to mass is proportional to the size of the particles in that stage cubed, which is a constant within one stage. However, this is not the case for the size fractions because these are also weighed by the particle size ranges.

Table 3. Spearman correlation coefficient rs between DR and particle number fractions, particle mass fractions, each stage separately and GMD.

No statistically significant correlation was found between DR and Ntot or between DR and mtot with both dilution systems. Also, no significant correlation was observed between DR and the size fractions with Dp > 0.01 µm which is in line with what Boman et al. (2005) concluded: The dilution ratio has no statistically significant influence on the total particle concentration for particles from wood combustion with an aerodynamic diameter between 0.03 and 10 µm. Hedberg et al. (2002) found that the size distributions from wood combustion were not severely affected by DR when measuring with a differential mobility particle sizer (DMPS) with a range of 3–920 nm. However, based on our measurements, Stage 1 of both ELPI+’s show a very strong positive correlation with DR. During high load operation, this correlation appears to be statistically significant while at the other operation modes this correlation is not significant (due to the limited number of tests). This is in accordance with what was already visually observed in the particle number size distributions (Figs. 6–9): An increase in DR leads to an increase of the smallest particles, measured in the ELPI+ Stage 1.

However, it is more likely that this correlation is the result of measurement artefacts rather than aerosol dynamics. To illustrate this, in Fig. 11 the correlation between DR and the particles in Stage 1 when diluting with the PTD + ED is shown for different boiler operation modes. When applying linear regression models, rather high coefficients of determination are obtained (R2 > 0.98). Extrapolation of the models shows that at a DR of 1 (i.e., no dilution) 1.7 × 106, 1.1 × 106 and 3.0 × 104 particles cm–3 can be expected during respectively high load, low load and baghouse bypass. However, these values are only indicative due to the uncertainties related with extrapolation. The linear growth of the number of particles in Stage 1 with DR, and therefore with the amount of dilution air, indicates that the correlation can be the result of artefacts in the dilution air. The ELPI+ is electrically zeroed with air that is cleaned by passing through an internal HEPA filter. The dilution air is cleaned by, among other things, passing through a HEPA filter in the air cleaning unit. A higher particle collection efficiency of the HEPA filter in the ELPI+ for the particles Dp < 0.01 µm can cause a very strong correlation between DR and the particles measured in Stage 1. When the flue gases are diluted before measuring, the internal HEPA filter of the ELPI+ and the HEPA filter for cleaning the dilution air should have the same collection efficiency.

Fig. 11. Correlation between DR and particles measured in Stage 1 when diluting with PTD + ED; HL: high load, LL: low load, HL BB: high load with baghouse bypassed.Fig. 11. Correlation between DR and particles measured in Stage 1 when diluting with PTD + ED; HL: high load, LL: low load, HL BB: high load with baghouse bypassed.

When this condition can not be guaranteed, it is recommended to perform the ELPI+ zeroing with the dilution air instead of using the internal HEPA filtered air. This recommendation could reduce the need to exclude Stage 1 from experimental data measured with the ELPI+, an issue that often occurs. An analogous reasoning can be made with the DAD 100 but this is less pronounced because there is a relatively large variation between results with the same DR. The correlation could also be explained by various other processes, both measurement artefact and aerosol dynamic related, of which some are discussed in the supplementary material, but these are believed to be less likely or unlikely.

Observing Table 3, the DAD 100 dilution system shows a strong negative correlation between DR and the particles measured in Stage 8 (rs = –0.837), which is significant. This correlation with the DAD 100 can be the result of particle growth by condensation and adsorption at low dilution ratio. With condensation as main gas-particle transformation, reducing DR would lead to more condensation and thus result in a shift of the accumulation mode to the right, which was observed in Fig. 7. The occurring of condensation can be because of the fact that the DAD 100 uses lower DRs and a lower dilution air temperature (60°C) compared to the PTD + ED (150°C). The lower temperature with the DAD 100 is needed due to the temperature limit of the sample entering the ELPI+. With the PTD + ED a high temperature can be used in the PTD since the temperature is reduced in the ED. Also, the sampling probe of the DAD 100 was not heated. Condensation could occur in the probe between exiting the chimney and entering the dilution system, although this distance was limited to around 15 cm. The condensing substance can be water, since the flue gas contains about 17 vol% water, but also organic vapors are possible. Besides condensation, diluting with the DAD 100 (low DR, thus less particle-free dilution air injected) allows having more frequent collisions between particles leading to more agglomeration and coagulation resulting in less ‘small’ particles and more ‘large’ particles with decreasing DR. It is rather unlikely that only one type of process (condensation or collision) occurs, but rather a combination of processes will happen in the dilution systems. However, at these concentrations the coagulation rate is rather low and is of minor importance to consider, although coagulation is an ever-present phenomenon for aerosols (Wiinikka and Gebart, 2004; Wiinikka, 2005; Hinds, 2011).

From Table 3, it can be observed that there is a strong negative correlation between DR and GMD for both the PTD + ED (rs = –0.986) and the DAD 100 (rs = –0.896) which is the result of more ‘small’ particles and less ‘large’ particles with increasing dilution. This is a consequence of the correlation between DR and Stage 1.

The most appropriate DR strongly depends on the focus of the measurements. If a long measurement is required, a high DR is desirable to delay the overloading of the impactor. However, if a high measuring accuracy is required, a low DR is more desirable since the errors of measurements scale with DR. The suitable DR is thus a trade-off between the two. For this specific measurement setup and during high load without bypass, the compromise could result in a modest DR of about 20. However, to achieve the same durability for the measuring device during high load with bypass of the baghouse filters, the DR should be higher by more than a factor of 50. A discussion about the influence of DR on the sampling time until the overloading of the impactor can be found in the supplementary material.

In Fig. S6 the mutual relations between Ntot, mtot, GMD and DR are visually represented. With the DAD 100 dilution system there is a relatively wide spread between Ntot and GMD within the same operation mode compared with the PTD + ED dilution system.


Baghouse Collection Efficiency

In Fig. 12 the average baghouse collection efficiency per particle size with both dilution systems is shown and is calculated with the average number of particles in each stage during high load without bypass and with the average number of particles in each stage during bypass of the baghouse. Note that the impactors of both ELPI+’s were overloaded during the baghouse bypass tests and therefore the number of particles during these tests are possibly underestimated. With the PTD + ED dilution system, the collection efficiency is higher than 98.5% for particles with Dp > 0.05 µm whereas with the DAD 100 dilution system, the collection efficiency is higher than 97.9%. For particles with Dp < 0.05 µm the collection efficiency decreases drastically and even reaches zero with the DAD 100 dilution system as there were less particles measured in Stage 2 and 3 during the baghouse bypass than during high load without bypass. This lower collection efficiency for the smallest size fractions might be the reason why the smallest size fractions suggest the presence of a nuclei mode in the particle number size distribution. 

Fig. 12. Average baghouse collection efficiency per particle size.Fig. 12. Average baghouse collection efficiency per particle size.

 
CONCLUSIONS


The particulate emissions from a medium-scale biomass boiler in various operating modes were measured with two ELPI+s simultaneously using two different compact partial flow dilution systems. The following conclusions regarding the boiler operating mode, impactor greasing, dynamic behavior of impactors, impactor overloading and dilution conditions can be drawn.

The peak of the accumulation mode shifts to a larger particle size when the boiler load decreases. For particles with Dp > 0.05 µm, the baghouse filters exhibit a particle collection efficiency above 98.5% and 97.9% with the PTD + ED and DAD 100 dilution systems, respectively, but this efficiency drastically decreases for smaller particles.

When no grease is applied to the ELPI+ collection substrates, the particle concentration in Stage 1 is overestimated, whereas the concentrations in Stages 3 and 4 are underestimated, due to the increased particle bouncing. Thus, the total particle number concentration may increase by 4 times, with the concentration in Stage 1 potentially increasing by 10 times.

When the ELPI+ impactor is not overloaded, the particle concentrations of the N<0.01 and N0.01-0.1 fractions decrease over time due to the premature measurement of particles in the higher-numbered stages. Upon conducting a new measurement with a clean impactor, the concentrations for these fractions almost immediately decrease, whereas that for N0.1-1 slightly increases over time, because of this increasing effect. Considering this dynamic behavior of impactors when designing experiments and relating the particle load on the impactors to the measured concentrations when interpreting the results is recommended.

When the ELPI+ impactor is overloaded, piles of particles collect on the impactor plates and change the cut-off diameter of the impactor. This change in cut-off diameter shifts the peak of the accumulation mode towards larger particle sizes, resulting in an underestimation of the N0.1-1 and N0.01-0.1 concentrations. In addition, the saturated substrates can enhance the particle bouncing effect, thereby leading to an overestimated concentration for N<0.01. To delay the effects of overloading the impactor and prematurely measuring particles, oil-soaked sintered impactor plates can be used in the ELPI+.

No correlation between the DR and Ntot, mtot or the concentrations for the Dp > 0.01 µm size fractions is apparent with either dilution system. However, a very strong positive correlation is observed between the DR and the N<0.01 concentration with both systems. This correlation likely results from measurement artefacts induced by a difference in the HEPA filtered air between the ELPI+ zeroing and the dilution air. It is therefore recommended to either perform the zeroing with the dilution air or to ensure that the HEPA filters possess the same collection efficiency. Furthermore, with the DAD 100, the DR and the Stage 8 concentration display a negative correlation, and the peak of the accumulation mode shifts towards larger particle sizes as the DR decreases, thereby potentially promoting condensation. The occurrence of condensation may be due to the low DR, low dilution air temperature and use of an unheated probe. Both dilution systems aim to obtain a representative particle number size distribution of particulate emissions in the chimney. Provided that no measurement artefacts bias the results, the two-stage dilution system is preferred, as condensation may occur with the one-stage system. A dilution ratio of 20 is proposed as the recommended value for this measurement setup.

 

REFERENCES


  1. Amaral, S.S., de Carvalho Jr., J.A., Costa, M.A.M. and Pinheiro, C. (2015). An overview of particulate matter measurement instruments. Atmosphere 6: 1327–1345. [Publisher Site]

  2. Amaral, S.S., de Carvalho Jr., J.A., Costa, M.A.M. and Pinheiro, C. (2016). Particulate matter emission factors for biomass combustion. Atmosphere 7: 141. [Publisher Site]

  3. Auvinen, A., Lehtinen, K.E.J., Enriquez, J., Jokiniemi, J.K. and Zilliacus, R. (2000). Vaporisation rates of CsOH and CsI in conditions simulating a severe nuclear accident. J. Aerosol Sci. 31: 1029–1043. [Publisher Site]

  4. Biswas, P. and Thimsen, E. (2011). In Aerosol Measurement: Principles, Techniques, and Applications. Kulkarni, P., Baron, P.A. and Willeke, K. (Eds.), Wiley, Hoboken, New Jersey, Chapter 33, pp. 723–738. [Publisher Site]

  5. Boman, C., Nordin, A., Westerholm, R. and Pettersson, E. (2005). Evaluation of a constant volume sampling setup for residential biomass fired appliances - Influence of dilution conditions on particulate and PAH emissions. Biomass Bioenergy 29: 258–268. [Publisher Site]

  6. Brockmann, J.E. (2011). In Aerosol Measurement: Principles, Techniques, and Applications. Kulkarni, P., Baron, P.A. and Willeke, K. (Eds.), Wiley, Hoboken, New Jersey, Chapter 6, pp. 69–105. [Google Scholar]

  7. Chen, S.C., Tsai, C.J., Chen, H.D., Huang, C.Y. and Roam, G.D. (2011). The influence of relative humidity on nanoparticle concentration and particle mass distribution measurements by the MOUDI. Aerosol Sci. Technol. 45: 596–603. [Publisher Site]

  8. Chien, C.L., Tien, C.Y., Liu, C.N., Ye, H., Huang, W. and Tsai, C.J. (2015). Design and testing of the NCTU micro-orifice cascade impactor (NMCI) for the measurement of nanoparticle size distributions. Aerosol Sci. Technol. 49: 1009–1018. [Publisher Site]

  9. Christensen, K.A. and Livbjerg, H. (1996). A field study of submicron particles from the combustion of straw. Aerosol Sci. Technol. 25: 185–199. [Publisher Site]

  10. Coudray, N., Dieterlen, A., Roth, E. and Trouvé, G. (2009). Density measurement of fine aerosol fractions from wood combustion sources using ELPI distributions and image processing techniques. Fuel 88: 947–954. [Publisher Site]

  11. Dekati (2010). Dekati axial diluter DAD-100. User Manual ver. 2.0. Dekati Ltd., Tampere, Finland.

  12. Dekati (2016). Dekati ELPI+. User Manual ver. 1.54. Dekati Ltd., Tampere, Finland.

  13. Dhillon, R.S. and von Wuehlisch, G. (2013). Mitigation of global warming through renewable biomass. Biomass Bioenergy 48: 75–89. [Publisher Site]

  14. Dockery, D., Pope, C., Xu, X., Spengler, J., Ware, J., Fay, M., Ferris, B. and Speizer, F. (1993). An association between air pollution and mortality in six U.S. cities. N. Engl. J. Med. 329: 1753–1759. [Publisher Site]

  15. Dunbar, C., Kataya, A. and Tiangbe, T. (2005). Reducing bounce effects in the Andersen cascade impactor. Int. J. Pharm. 301: 25–32. [Publisher Site]

  16. Dyakov, I.V., Bergmans, B., Bram, S., De Ruyck, J. and Contino, F. (2016). Experimental study of particle emissions from a modern 5 kW pellet stove. Energy Res. J. 7: 19–23. [Publisher Site]

  17. Dzubay, T.G., Hines, L.E. and Stevens, R.K. (1976). Particle bounce errors in cascade impactors. Atmos. Environ. 10: 229–234. [Publisher Site]

  18. Fachinger, F., Drewnick, F., Gieré, R. and Borrmann, S. (2017). How the user can influence particulate emissions from residential wood and pellet stoves: Emission factors for different fuels and burning conditions. Atmos. Environ. 158: 216–226. [Publisher Site]

  19. Garra, P., Trouvé, G., Dieterlen, A. and Kohler, S. (2016). Impactors long term collection errors and correction using reflected light microscopy. J. Aerosol Sci. 91: 1–14. [Publisher Site]

  20. Giechaskiel, B., Maricq, M., Ntziachristos, L., Dardiotis, C., Wang, X., Axmann, H., Bergmann, A. and Schindler, W. (2014). Review of motor vehicle particulate emissions sampling and measurement: From smoke and filter mass to particle number. J. Aerosol Sci. 67: 48–86. [Publisher Site]

  21. Grieshop, A.P., Logue, J.M., Donahue, N.M. and Robinson, A.L. (2009). Laboratory investigation of photochemical oxidation of organic aerosol from wood fires 1: Measurement and simulation of organic aerosol evolution. Atmos. Chem. Phys. 9: 1263–1277. [Publisher Site]

  22. Grigonyte, J., Nuutinen, I., Koponen, T., Lamberg, H., Tissari, J., Jokiniemi, J. and Sippula, O. (2014). Evaluation of a heat exchanger designed for efficient fine particle precipitation in small-scale wood combustion. Energy Fuels 28: 6058–6065. [Publisher Site]

  23. Hasler, P. and Nussbaumer, T. (1999). Gas cleaning for IC engine applications from fixed bed biomass gasification. Biomass Bioenergy 16: 385–395. [Publisher Site]

  24. Hedberg, E., Kristensson, A., Ohlsson, M., Johansson, C., Åke Johansson, P., Swietlicki, E., Vesely, V., Wideqvist, U. and Westerholm, R. (2002). Chemical and physical characterization of emissions from birch wood combustion in a wood stove. Atmos. Environ. 36: 4823–4837. [Publisher Site]

  25. Hinds, W.C. (1999). Aerosol technology: Properties, behavior, and measurement of airborne particles, 2nd ed., Wiley, Hoboken, New Jersey.

  26. Hinds, W.C. (2011). In Aerosol Measurement: Principles, Techniques, and Applications. Kulkarni, P., Baron, P.A. and Willeke, K. (Eds.), Wiley, Hoboken, New Jersey, Chapter 3, pp. 31–40. [Google Scholar]

  27. Hueglin, C., Gaegauf, C., Künzel, S. and Burtscher, H. (1997). Characterization of wood combustion particles: Morphology, mobility, and photoelectric activity. Environ. Sci. Technol. 31: 3439–3447. [Publisher Site]

  28. Järvinen, A., Aitomaa, M., Rostedt, A., Keskinen, J. and Yli-Ojanperä, J. (2014). Calibration of the new electrical low pressure impactor (ELPI+). J. Aerosol Sci.  69: 150–159. [Publisher Site]

  29. Johansson, L.S., Tullin, C., Leckner, B. and Sjövall, P. (2003). Particle emissions from biomass combustion in small combustors. Biomass Bioenergy 25: 435–446. [Publisher Site]

  30. John, W. (2011). In Aerosol measurement: Principles, Techniques, and Applications, Kulkarni, P., Baron, P.A. and Willeke, K. (Eds.), Wiley, Hoboken, New Jersey, Chapter 4, pp. 41–54. [Google Scholar]

  31. Jöller, M., Brunner, T. and Obernberger, I. (2005). Modeling of aerosol formation during biomass combustion in grate furnaces and comparison with measurements. Energy Fuels 19: 311–323. [Publisher Site]

  32. Kaivosoja, T., Jalava, P.I., Lamberg, H., Virén, A., Tapanainen, M., Torvela, T., Tapper, U., Sippula, O., Tissari, J., Hillamo, R., Hirvonen, M.R. and Jokiniemi, J. (2013). Comparison of emissions and toxicological properties of fine particles from wood and oil boilers in small (20-25 kW) and medium (5-10 MW) scale. Atmos. Environ. 77: 193–201. [Publisher Site]

  33. Kim, S., Bell, M., Hashizume, M., Honda, Y., Kan, H. and Kim, H. (2018). Associations between mortality and prolonged exposure to elevated particulate matter concentrations in East Asia. Environ. Int. 110: 88–94. [Publisher Site]

  34. Kittelson, D.B., Watts, W.F. and Johnson, J.P. (2006). On-road and laboratory evaluation of combustion aerosols - Part 1: Summary of diesel engine results. J. Aerosol Sci. 37: 913–930. [Publisher Site]

  35. Krugly, E., Martuzevicius, D., Puida, E., Buinevicius, K., Stasiulaitiene, I., Radziuniene, I., Minikauskas, A. and Kliucininkas, L. (2014). Characterization of gaseous- and particle-phase emissions from the combustion of biomass-residue-derived fuels in a small residential boiler. Energy Fuels 28: 5057–5066. [Publisher Site]

  36. Kuuluvainen, H., Arffman, A., Järvinen, A., Harra, J. and Keskinen, J. (2017). The effect of materials and obliquity of the impact on the critical velocity of rebound. Aerosol Sci. Technol. 51: 301–310. [Publisher Site]

  37. Lamberg, H., Nuutinen, K., Tissari, J., Ruusunen, J., Yli-Pirilä, P., Sippula, O., Tapanainen, M., Jalava, P., Makkonen, U., Teinilä, K., Saarnio, K., Hillamo, R., Hirvonen, M.R. and Jokiniemi, J. (2011). Physicochemical characterization of fine particles from small-scale wood combustion. Atmos. Environ. 45: 7635–7643. [Publisher Site]

  38. Le, T.C. and Tsai, C.J. (2017). Novel non-bouncing PM2.5 impactor modified from well impactor ninety-six. Aerosol Sci. Technol. 51: 1287–1295. [Publisher Site]

  39. Le, T.C., Shukla, K.K., Sung, J.C., Li, Z., Yeh, H., Huang, W. and Tsai, C.J. (2019). Sampling efficiency of low-volume PM10 inlets with different impaction substrates. Aerosol Sci. Technol. 53: 295–308. [Publisher Site]

  40. Lillieblad, L., Szpila, A., Strand, M., Pagels, J., Rupar-Gadd, K., Gudmundsson, A., Swietlicki, E., Bohgard, M. and Sanati, M. (2004). Boiler operation influence on the emissions of submicrometer-sized particles and polycyclic aromatic hydrocarbons from biomass-fired grate boilers. Energy Fuels 18: 410–417. [Publisher Site]

  41. Lyyränen, J., Jokiniemi, J., Kauppinen, E.I., Backman, U. and Vesala, H. (2004). Comparison of different dilution methods for measuring diesel particle emissions. Aerosol Sci. Technol. 38: 12–23. [Publisher Site]

  42. McDonald, J.D., Zielinska, B., Fujita, E.M., Sagebiel, J.C., Chow, J.C. and Watson, J.G. (2000). Fine particle and gaseous emission rates from residential wood combustion. Environ. Sci. Technol. 34: 2080–2091. [Publisher Site]

  43. McKendry, P. (2002). Energy production from biomass (Part 1): Overview of biomass. Bioresour. Technol. 83: 37–46. [Publisher Site]

  44. Mertens, J., Brachert, L., Desagher, D., Schallert, B., Khakharia, P. and Goetheer, E. (2014). Predicting amine mist formation based on aerosol number concentration and size measurements in flue gas. Energy Procedia 63: 893–901. [Publisher Site]

  45. Mertens, J., Bruns, R., Schallert, B., Faniel, N., Khakharia, P., Albrecht, W., Goetheer, E., Blondeau, J. and Schaber, K. (2015). Effect of a gas-gas-heater on H2SO4 aerosol formation: Implications for mist formation in amine based carbon capture. Int. J. Greenhouse Gas Control 39: 470–477. [Publisher Site]

  46. Nussbaumer, T. (2003). Combustion and co-combustion of biomass: Fundamentals, technologies, and primary measures for emission reduction. Energy Fuels 17: 1510–1521. [Publisher Site]

  47. Oberdörster, G., Ferin, J. and Lehnert, B.E. (1994). Correlation between particle size, in vivo particle persistence, and lung injury. Environ. Health Perspect. 102: 173–179. [Publisher Site]

  48. Pagels, J., Johansson, L., Hagström, M., Wierzbicka, A., Bohgard, M., Tullin, C. and Sanat, M. (2002). Intercomparison of SMPS, ELPI and APS 3320 during sampling of particles emitted from a domestic wood pellet burner. 6th International Aerosol Conference, Taipei, Taiwan.

  49. Pagels, J., Strand, M., Rissler, J., Szpila, A., Gudmundsson, A., Bohgard, M., Lillieblad, L., Sanati, M. and Swietlicki, E. (2003). Characteristics of aerosol particles formed during grate combustion of moist forest residue. J. Aerosol Sci. 34: 1043–1059. [Publisher Site]

  50. Pak, S.S., Liu, B.Y.H. and Rubow, K.L. (1992). Effect of coating thickness on particle bounce in inertial impactors. Aerosol Sci. Technol. 16: 141–150. [Publisher Site]

  51. Peters, T.M., Vanderpool, R.W. and Wiener, R.W. (2001). Design and calibration of the EPA PM2.5 well impactor ninety-six (WINS). Aerosol Sci. Technol. 34: 389–397. [Publisher Site]

  52. Schmid, O. and Stoeger, T. (2016). Surface area is the biologically most effective dose metric for acute nanoparticle toxicity in the lung. J. Aerosol Sci. 99: 133–143. [Publisher Site]

  53. Sippula, O., Hytönen, K., Tissari, J., Raunemaa, T. and Jokiniemi, J. (2007). Effect of wood fuel on the emissions from a top-feed pellet stove. Energy Fuels 21: 1151–1160. [Publisher Site]

  54. Soltero, V.M., Chacartegui, R., Ortiz, C. and Veléazquez, R. (2018). Potential of biomass district heating systems in rural areas. Energy 156: 132–143. [Publisher Site]

  55. Strand, M., Pagels, J., Szpila, A., Gudmundsson, A., Swietlicki, E., Bohgard, M. and Sanati, M. (2002). Fly ash penetration through electrostatic precipitator and flue gas condenser in a 6 MW biomass fired boiler. Energy Fuels 16: 1499–1506. [Publisher Site]

  56. Tissari, J., Hytönen, K., Lyyränen, J. and Jokiniemi, J. (2007). A novel field measurement method for determining fine particle and gas emissions from residential wood combustion. Atmos. Environ. 41: 8330–8344. [Publisher Site]

  57. Tissari, J., Lyyränen, J., Hytönen, K., Sippula, O., Tapper, U., Frey, A., Saarnio, K., Pennanen, A., Hillamo, R., Salonen, R., Hirvonen, M.R. and Jokiniemi, J. (2008a). Fine particle and gaseous emissions from normal and smouldering wood combustion in a conventional masonry heater. Atmos. Environ. 42: 7862–7873. [Publisher Site]

  58. Tissari, J., Sippula, O., Kouki, J., Vuorio, K. and Jokiniemi, J. (2008b). Fine particle and gas emissions from the combustion of agricultural fuels fired in a 20 kW burner. Energy Fuels 22: 2033–2042. [Publisher Site]

  59. Torvela, T., Tissari, J., Sippula, O., Kaivosoja, T., Leskinen, J., Virén, A., Lähde, A. and Jokiniemi, J. (2014). Effect of wood combustion conditions on the morphology of freshly emitted fine particles. Atmos. Environ. 87: 65–76. [Publisher Site]

  60. Tsai, C.J. and Cheng, Y.H. (1995). Solid particle collection characteristics on impaction surfaces of different designs. Aerosol Sci. Technol. 23: 96–106. [Publisher Site]

  61. Tsai, C.J., Liu, C.N., Hung, S.M., Chen, S.C., Uang, S.N., Cheng, Y.S. and Zhou, Y. (2012). Novel active personal nanoparticle sampler for the exposure assessment of nanoparticles in workplaces. Environ. Sci. Technol. 46: 4546–4552. [Publisher Site]

  62. Turner, J.R. and Hering, S.V. (1987). Greased and oiled substrates as bounce-free impaction surfaces. J. Aerosol Sci. 18: 215–224. [Publisher Site]

  63. Valmari, T., Kauppinen, E.I., Kurkela, J., Jokiniemi, J.K., Sfiris, G. and Revitzer, H. (1998). Fly ash formation and deposition during fluidized bed combustion of willow. J. Aerosol Sci. 29: 445–459. [Publisher Site]

  64. van Gulijk, C., Schouten, J.M., Marijnissen, J.C.M., Makkee, M. and Moulijn, J.A. (2001). Restriction for the ELPI in diesel particulate measurements. J. Aerosol Sci. 32: 1117–1130. [Publisher Site]

  65. van Gulijk, C., Marijnissen, J.C.M., Makkee, M. and Moulijn, J.A. (2003). Oil-soaked sintered impactors for the ELPI in diesel particulate measurements. J. Aerosol Sci. 34: 635–640. [Publisher Site]

  66. van Gulijk, C., Marijnissen, J.C.M., Makkee, M., Moulijn, J.A. and Schmidt-Ott, A. (2004). Measuring diesel soot with a scanning mobility particle sizer and an electrical low-pressure impactor: Performance assessment with a model for fractal-like agglomerates. J. Aerosol Sci. 35: 633–655. [Publisher Site]

  67. Virtanen, A., Joutsensaari, J., Koop, T., Kannosto, J., Yli-Pirilä, P., Leskinen, J., Mäkelä, J.M., Holopainen, J.K., Pöschl, U., Kulmala, M., Worsnop, D.R. and Laaksonen, A. (2010). An amorphous solid state of biogenic secondary organic aerosol particles. Nature 467: 824–827. [Publisher Site]

  68. Whitby, K.T. (1978). The physical characteristics of sulfur aerosols. Atmos. Environ. 12: 135–159. [Publisher Site]

  69. WHO (2013). Health effects of particulate matter. Policy implications for countries in eastern Europe, Caucasus and central Asia. World Health Organization.

  70. Wierzbicka, A., Lillieblad, L., Pagels, J., Strand, M., Gudmundsson, A., Gharibi, A., Swietlicki, E., Sanati, M. and Bohgard, M. (2005). Particle emissions from district heating units operating on three commonly used biofuels. Atmos. Environ. 39: 139–150. [Publisher Site]

  71. Wiinikka, H. and Gebart, R. (2004). Critical parameters for particle emissions in small-scale fixed-bed combustion of wood. Energy Fuels 18: 897–907. [Publisher Site]

  72. Wiinikka, H. (2005). High temperature aerosol formation and emission minimization during combustion of wood pellets. Ph.D. thesis. Luleå University of Technology. Luleå, Sweden.


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

7.3
2022CiteScore
 
 
77st percentile
Powered by
Scopus
 
   SCImago Journal & Country Rank

2022 Impact Factor: 4.0
5-Year Impact Factor: 3.4

The Future Environment and Role of Multiple Air Pollutants

Aerosol and Air Quality Research partners with Publons

CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit
CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.