Huang, K.L., Liao, Y.H. and Chen, S.J. (2019). Effects of Operating Parameters on Gas-phase PAH Emissions from a Direct Methanol Fuel Cell. Aerosol Air Qual. Res. 19: 2196-2204. https://doi.org/10.4209/aaqr.2019.08.0388


Highlights

  • Gas-phase PAHs emitted from a DMFC for various runs are compared.
  • The PAHs have different concentration profiles in various stage samplings or runs.
  • Decreasing O2 flowrate exhibits the lowest PAH emission among tested runs.
  • The DMFC had the lowest performance when the cell temperature was 60°C.
  • The emission factor sums of Total-PAHs are 0.07 ± 0.03–2.44 ± 0.52 µg g-electrode–1.

ABSTRACT


This study aims at investigating the emissions of cathode gas-phase polycyclic aromatic hydrocarbons (PAHs) from a single direct methanol fuel cell (DMFC) at different operating parameters (methanol concentration, methanol flowrate, oxygen flowrate, and cell temperature). At the standard test condition (run A1), the concentrations of stage 1 (S1) and S2 PAHs ranged from non-detect (ND) to 10.3 ± 2.54 (Nap) and ND to 0.148 ± 0.047 (IND) µg Nm–3, respectively; furthermore, the Total-PAHs and Total-BaPeq concentrations of S1 + S2 were 21.2 ± 4.48 µg Nm–3 and 409 ± 226 ng Nm–3, respectively. The operating parameters significantly influenced the patterns of PAH concentration profiles. Decreasing with increasing methanol flowrate and concentration or decreasing oxygen flowrate and cell temperature, the ranges of Total-PAHs and Total-BaPeq concentrations of S1 + S2 for different runs were (36.4 ± 10.9)‒(0.98 ± 0.21) µg Nm–3 and (409 ± 226)‒(98.7 ± 30.3) ng Nm–3, respectively, with corresponding emission factors from 0.07 ± 0.03 to 2.44 ± 0.52 µg g-electrode–1 and from 7.58 ± 2.32 to 47.1 ± 26.0 ng g-electrode–1, respectively. At the same operating condition, more cathode gas-phase Total-PAHs and Total-BaPeq emissions were observed for the DMFC using a HE membrane-electrode assembly (MEA) than for using an E-TEK MEA. The DMFC had the lowest performance when the cell temperature was 60°C.


Keywords: Polycyclic aromatic hydrocarbon (PAH); Direct methanol fuel cell; Emission factor; Gas-phase PAH.

 



Don't forget to share this article 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

Latest coronavirus research from Aerosol and Air Quality Research

2018 Impact Factor: 2.735

5-Year Impact Factor: 2.827


SCImago Journal & Country Rank

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal, promotes submissions of high-quality research, and strives to be one of the leading aerosol and air quality open-access journals in the world.