Xiaotong Chen1,2, Qiaoling Liu2, Jingkun Jiang1, Da-Ren Chen 2


State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
Particle Laboratory, Department of Mechanical and Nuclear Engineering, School of Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA



Received: February 19, 2018
Revised: April 13, 2018
Accepted: April 19, 2018
Download Citation: ||https://doi.org/10.4209/aaqr.2018.02.0060  


Cite this article:
Chen, X., Liu, Q., Jiang, J. and Chen, D.R. (2018). Performance of Small Plate and Tube Unipolar Particle Chargers at Low Corona Current. Aerosol Air Qual. Res. 18: 2005-2013. https://doi.org/10.4209/aaqr.2018.02.0060


HIGHLIGHTS

  • The performance of small -tube and -plate unipolar particle chargers was evaluated.
  • Studied unipolar chargers were operated at low corona discharge current.
  • Tested particle chargers were designed for compact mobility-based particle sizers.
  • Small-plate charger attaches less charge on particles than small-tube charger.

ABSTRACT


Two small chargers, a plate and a tube particle charger, were compared in terms of their performance at low DC-corona current. Both chargers are designed for compact/miniature electrical-mobility-based particle sizers and were operated at a corona current of 0.3 µA for simultaneous low energy consumption and high charging efficiency. A thin wire was utilized in the plate charger for the ion generation via the DC-corona discharge, while a sharp-tipped needle was used in the tube charger. The intrinsic and extrinsic charging efficiencies of particles in various electrical mobility sizes were measured for both chargers at aerosol flow rates of 0.3 and 0.6 L min–1. In general, the plate charger exhibited a lower intrinsic charging efficiency than the tube charger. Also, its extrinsic charging efficiency was slightly higher at 0.3 L min–1 than 0.6 L min–1 and reached approximately 80% for particles larger than 40 nm. On the other hand, the extrinsic charging efficiency of the tube charger was higher at 0.6 L min–1 than 0.3 L min–1 for particles larger than 60 nm, with the reverse being true for smaller particles. The extrinsic charge distributions of particles with mobility sizes smaller than 300 nm were also characterized. It was found that a multiple-charge status occurred on particles larger than 20 nm for both chargers. At the same particle size, more charges attached to particles in the tube charger than the plate charger. The birth-and-death charging model was proposed for calculating the extrinsic charge distributions of particles measured in this study. In addition, the Gaussian distribution function was also suggested for best fitting the measured extrinsic charge distributions of particles.


Keywords: Compact/miniature aerosol charger; DC-corona unipolar charger; Small tube charger; Small plate charger; Ultrafine and fine particles.

 



Don't forget to share this article 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

Latest coronavirus research from Aerosol and Air Quality Research

2018 Impact Factor: 2.735

5-Year Impact Factor: 2.827


SCImago Journal & Country Rank

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal, promotes submissions of high-quality research, and strives to be one of the leading aerosol and air quality open-access journals in the world.