Norbert Serfozo 1, Jakub Ondráček2, Naděžda Zíková2, Mihalis Lazaridis1, Vladimír Ždímal2

  • 1 School of Environmental Engineering, Technical University of Crete, Polytechneioupolis, 73100 Chania, Greece
  • 2 Institute of Chemical Process Fundamentals, v.v.i., Academy of Sciences of the Czech Republic, Rozvojová 135, 16502 Prague, Czech Republic

Received: September 7, 2016
Revised: December 22, 2016
Accepted: January 4, 2017
Download Citation: ||https://doi.org/10.4209/aaqr.2016.09.0390  

  • Download: PDF


Cite this article:
Serfozo, N., Ondráček, J., Zíková, N., Lazaridis, M. and Ždímal, V. (2017). Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators. Aerosol Air Qual. Res. 17: 1305-1315. https://doi.org/10.4209/aaqr.2016.09.0390


HIGHLIGHTS

  • Size-resolved penetration (CMD) of 13 CE-marked FFRs were measured experimentally.
  • 47 mm filters were cut out and challenged with monodisperse ammonium sulfate.
  • Two filters from same FFR and two identical half masks from each FFR were examined.
  • Methodology of currently valid EN149:2001 was compared to our size-resolved method.

 

ABSTRACT


Throughout the years, the performance of the FFRs has been the topic of extensive studies, resulting mainly in the characterization of aerosol penetration through filters using aerosols that are thought to be similar to those encountered in workplaces. There are limited number of studies in the literature reporting CE-marked respirator performance, and there is a need to perform a penetration evaluation of CE-marked respirators through all 3 filtering classes: FFP1 (80%), FFP2 (94%), and FFP3 (99%). In this study, the percentage penetrations and the most penetrating particle size (MPPS) of 47 mm filters cut out from 13 different CE-marked respirator half masks (2 samples of each FFR) were evaluated size-selectively using nine sizes of charge-neutralized monodisperse aerosol, which ranged from 20 to 400 nm (CMD). Comparison of the penetrations at MPPS from all the examined filters showed that the percentage penetration ranged 3.2–16.3% (FFP1), 2.4–34.3% (FFP2), and 0.02–3.3% (FFP3). Experimental data also revealed that the penetration difference between 2 samples from the same respirator was in most cases up to 6.8%, and between 2 identical respirators up to 2.5%. The MPPS was found to be between 30 and 60 nm (CMD) in all measurements. By comparing the obtained results to the European Standard we conclude that the standard method underestimates particle penetration (especially for particles < 100 nm) due to the usage of non neutralized, polydisperse test aerosol, detection methods burdened with measurement artifacts, and the assumption that the MPPS is at ≈ 600 nm (MMD) as the criterion for filtering facepieces to pass the penetration test.


Keywords: Size-resolved penetration; CE-marked respirator; Monodisperse ammonium sulfate; 47 mm filter sample; EN 149


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

7.3
2022CiteScore
 
 
77st percentile
Powered by
Scopus
 
   SCImago Journal & Country Rank

2022 Impact Factor: 4.0
5-Year Impact Factor: 3.4

Call for Papers for the special issue on: "Carbonaceous Aerosols in the Atmosphere"

Aerosol and Air Quality Research partners with Publons

CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit
CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.