Qiang Wang, Laleh Golshahi , Da-Ren Chen

  • Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA

Received: August 29, 2016
Revised: November 25, 2016
Accepted: December 4, 2016
Download Citation: ||https://doi.org/10.4209/aaqr.2016.08.0375  


Cite this article:
Wang, Q., Golshahi, L. and Chen, D.R. (2017). Evaluation of Respirator Filter Media under Inhalation-only Conditions. Aerosol Air Qual. Res. 17: 2681-2690. https://doi.org/10.4209/aaqr.2016.08.0375


HIGHLIGHTS

  • The effects of breathing frequency and peak inhalation flowrate were studied.
  • Breathing frequency has its noticeable effect on particle penetration of filters.
  • The new ratio of peak particle penetration was introduced.
  • Semi-theoretical model was developed to find the peak penetration of filter media.

 

ABSTRACT


Filter media for respirator applications are typically exposed to cyclic flow condition instead of constant flow adopted in the standard filter media tests. The objective of this study is thus to investigate the effects of breathing frequency (BF) and peak inhalation flow rate (PIFR) on the peak particle penetration of respirator filter media, especially for particles at the most penetration particle sizes under the constant flow condition having equivalent mean inhalation flowrate (MIFR). Five respirator filter media were evaluated under inhalation-only conditions. Three BFs and three PIFRs were selected for the testing. Our study evidenced that both BF and PIFR would increase the peak particle penetration under the cyclic inhalation-only conditions. It is further found that, for each filter media, the peak particle penetration at various PIFRs could be merged into one curve via the newly-defined peak penetration ratio (i.e., the ratio of peak particle penetration at cyclic flow condition to the penetration at the constant flow condition having the equivalent MIFR) and the curve is only a function of BF. The above observation indicates that the increase of peak particle penetration resulted from the increase of PIFR is simply because of the increase of MIFR. The effect of BF on the peak particle penetration is clearly observed using the defined penetration ratio. Based on our finding a semi-theoretical model was further proposed to estimate the peak particle penetration of respirator filter media under inhalation-only conditions.


Keywords: Breathing frequency (BF); Inhalation-only testing; Peak inhalation flowrate (PIFR); Respirator filter media


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

7.3
2022CiteScore
 
 
77st percentile
Powered by
Scopus
 
   SCImago Journal & Country Rank

2022 Impact Factor: 4.0
5-Year Impact Factor: 3.4

Call for Papers for the special issue on: "Carbonaceous Aerosols in the Atmosphere"

Aerosol and Air Quality Research partners with Publons

CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit
CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.