Dong Hee Choi1, Dong Hwa Kang 2

  • 1 Department of Architectural Engineering, College of Engineering, Kyungil University, Gyeongbuk 38428, Korea
  • 2 Department of Architectural Engineering, College of Urban Sciences, University of Seoul, Seoul 02504, Korea

Received: June 30, 2016
Revised: September 27, 2016
Accepted: February 2, 2017
Download Citation: ||https://doi.org/10.4209/aaqr.2016.06.0287  

  • Download: PDF


Cite this article:
Choi, D.H. and Kang, D.H. (2017). Infiltration of Ambient PM2.5 through Building Envelope in Apartment Housing Units in Korea. Aerosol Air Qual. Res. 17: 598-607. https://doi.org/10.4209/aaqr.2016.06.0287


HIGHLIGHTS

  • The infiltration of ambient PM2.5 in apartment housing units was investigated.
  • The on-site test method by using a blower-door depressurization was suggested.
  • The infiltration tests were conducted in 11 apartment housing units.
  • A leaky housing units would be significantly influenced by ambient PM2.5.

 

ABSTRACT


Air pollution due to PM2.5 is of public concern in Korea. Ambient PM2.5 can penetrate indoors through the building envelope, affecting the indoor PM2.5 concentrations. Most people stay indoors for approximately 80% of every day, implying that their primary exposure to PM2.5 could be determined by the indoor air. This study aims to investigate the infiltration of ambient PM2.5 through the building envelop in apartment housing units in Korea. The on-site infiltration test method, by using a blower-door depressurization procedure, was suggested in order to maintain an identical indoor-outdoor pressure difference among the tests. On-site experiments were conducted in 11 apartment housing units to estimate the PM2.5 infiltration factors. The results showed that the average infiltration factor of all the test housing units was 0.65 ± 0.13 (average ± standard deviation), with a minimum of 0.38 and a maximum of 0.88. Furthermore, the results from the relation of the building airtightness data to the infiltration factors suggests that a leaky housing unit with high ACH50, or a high specific effective leakage area (ELA), would be more significantly influenced by the ambient PM2.5. The study demonstrated that the suggested infiltration test procedure was useful to assess the infiltration factors in conditions of controlled indoor-outdoor pressure differences in real housing units.


Keywords: PM2.5; Indoor air quality; Infiltration; Building envelope; Apartment housing unit; Blower-door testing


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

7.3
2022CiteScore
 
 
77st percentile
Powered by
Scopus
 
   SCImago Journal & Country Rank

2021 Impact Factor: 4.53
5-Year Impact Factor: 3.668

The Future Environment and Role of Multiple Air Pollutants

Aerosol and Air Quality Research partners with Publons

CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit
CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.