Ilnar T. Mukhametzanov1, Sergey A. Grinshpun 2, Shamil K. Zaripov 1, Artur K. Gilfanov1

  • 1 Kazan Federal University, Kazan 420008, Russia
  • 2 Center for Health-Related Aerosol Studies, University of Cincinnati, Ohio 45267-0056, USA

Received: August 10, 2016
Revised: February 28, 2016
Accepted: March 1, 2016
Download Citation: ||https://doi.org/10.4209/aaqr.2015.07.0466  

  • Download: PDF


Cite this article:
Mukhametzanov, I.T., Grinshpun, S.A., Zaripov, S.K. and Gilfanov, A.K. (2016). Assessing the Protection Provided by Facepiece Filtering Respirator: New Model Involving Spherical Porous Layer with Annular Peripheral Opening. Aerosol Air Qual. Res. 16: 2428-2437. https://doi.org/10.4209/aaqr.2015.07.0466


HIGHLIGHTS

  • A model was developed for the performance of a respirator with faceseal leakage.
  • The particle penetration through the filter versus faceseal leakage was assessed.
  • The leakage-to-filter area ratio has a major effect on the respirator performance.
  • The effects of particle size, leak dimension, and breathing flow were quantified.

 

ABSTRACT


The penetration of aerosol particles inside a facepiece filtering respirator (FFR) was investigated using a novel model, which involved a spherical porous layer representing a filter and an annular peripheral opening representing a faceseal leakage. The model utilized a two-dimensional laminar incompressible flow in a free space and porous zones that are numerically solved by a computational fluid dynamic code FLUENT. Following the model validation, the efficiency of an FFR with an annular faceseal leakage opening was investigated as a function of the inhalation flow rate, particle size, and the ratio of the leak-to-filter areas. The filter material permeability was determined for a conventional N95 filter medium. It was found – for two inhalation flow rates (Qi = 30 and 85 L min–1) and three particle diameters (dp = 50 nm, 100 nm and 1 µm) – that once the faceseal leakage area exceeded 0.1% of the total surface of an N95 facepiece, the respirator was unable to offer the 95% protection – the minimum level that should be provided by its filter. It was demonstrated that under certain leakage condition (partially determined by the inhalation flow rate), the respirator protection level becomes independent on the particle size; furthermore, it is not anymore affected by the efficiency of its filter, and is only influenced by the size of the faceseal leakage.


Keywords: Respiratory protection; Penetration; Filter; Faceseal leakage; CFD


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

7.3
2022CiteScore
 
 
77st percentile
Powered by
Scopus
 
   SCImago Journal & Country Rank

2022 Impact Factor: 4.0
5-Year Impact Factor: 3.4

Call for Papers for the special issue on: "Carbonaceous Aerosols in the Atmosphere"

Aerosol and Air Quality Research partners with Publons

CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit
CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.