Ping-Yun Huang1, Zhi-Yuan Shi2, Chi-Hao Chen1, Walter Den 1, Hui-Mei Huang3, Jaw-Ji Tsai4

  • 1 Department of Environmental Science and Engineering, Tunghai University, No. 181, Sec. 3, Taichung Port Road, Taichung City 40704, Taiwan
  • 2 Section of Infectious Diseases, Department of Internal Medicine, Taichung Veteran General Hospital, No. 160, Sec. 3, Taichung Port Road, Taichung 40705, Taiwan
  • 3 Department of Nursing, Taichung Veteran General Hospital, No. 160, Sec. 3, Taichung Port Road, Taichung 40705, Taiwan
  • 4 Section of Allergy and Immunology, Taichung Veterans General Hospital, Taichung 40705, Taiwan

Received: August 20, 2012
Revised: December 10, 2012
Accepted: December 10, 2012
Download Citation: ||https://doi.org/10.4209/aaqr.2012.08.0217  

  • Download: PDF


Cite this article:
Huang, P.Y., Shi, Z.Y., Chen, C.H., Den, W., Huang, H.M. and Tsai, J.J. (2013). Airborne and Surface-Bound Microbial Contamination in Two Intensive Care Units of a Medical Center in Central Taiwan. Aerosol Air Qual. Res. 13: 1060-1069. https://doi.org/10.4209/aaqr.2012.08.0217


 

ABSTRACT


Samples of airborne and surface-bound microbial contamination were taken in two intensive care units of a large-scale medical center. Microbial analyses included total bacterial and fungal loads, as well as the four bacterial species of Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa and Acinetobacter baumannii. Among the 114 surface samples taken from seven designated surface locations of room and equipment for each patient, P. aeruginosa was the most frequently detected (19.3%) and most abundant (mean count: 4.18 cfu/plate) bacterium, whereas the respirator represented the most heavily contaminated surface location in both total pathogenic bacteria colony counts (272 cfu) and frequency of positive detection (38.2%). P. aeruginosa also represented the most frequently detected (39.1%, n = 46) and abundant (11.52 ± 17.16 cfu/m3) bacterium in the air samples (n = 46), and was the only bacterium exhibiting a positive correlation of the mean counts between air and surface samples. The data analysis results further suggested a higher value of relative risk among the infected patients in the presence of the pathogens as compared to those in the absence of them, although the evidence of a of correlation for the individual bacterial species between the environmental samples and infected patients was inconclusive. This study also found that the mean airborne counts and the detection frequencies of these bacteria after patient visitation periods were higher than those before visitation, and that the installation of local air ionizers did not lead to any discernible differences in total bacterial and fungal concentrations.


Keywords: Indoor air quality; Nosocomial infection; Airborne pathogens; Intensive care units; Hospital environment


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

5.9
2020CiteScore
 
 
81st percentile
Powered by
Scopus


Aerosol and Air Quality Research partners with Publons

Special Call for Papers Air Pollution and its impact in South and Southeast Asia

2020 Impact Factor: 3.063
5-Year Impact Factor: 2.857

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.