Haryono S. Huboyo 1, Susumu Tohno1, Renqiu Cao2

  • 1 Dept of Socio-Environmental Energy Science, Graduate School of Energy Science, Kyoto University, Sakyo-ku, Kyoto 606-8501, Japan
  • 2 Tokyo Dylec Co., Shinjuku-ku, Tokyo 160-0014, Japan

Received: February 26, 2011
Revised: May 20, 2011
Accepted: May 20, 2011
Download Citation: ||https://doi.org/10.4209/aaqr.2011.02.0016  

  • Download: PDF


Cite this article:
Huboyo, H.S., Tohno, S. and Cao, R. (2011). Indoor PM2.5 Characteristics and CO Concentration Related to Water-Based and Oil-Based Cooking Emissions Using a Gas Stove. Aerosol Air Qual. Res. 11: 401-411. https://doi.org/10.4209/aaqr.2011.02.0016


 

ABSTRACT


Pollutant emissions from indoor cooking activities using clean fuels such as natural gas or LPG are strongly influenced by cooking ingredients and cooking methods. In this study, we explore the characterization of indoor fine particles (PM2.5) and CO that are produced by two distinctive cooking methods: frying and boiling. This characterization includes quantifying the presence of fine particles in a kitchen as well as in the adjoining room, analyzing size-segregated carbonaceous materials (EC and OC), and identifying variations in CO associated with the cooking method. Four monitoring devices—a UCB particle monitor, an optical particle counter, a cascade impactor, and a CO monitor—were simultaneously used to measure temporal variations in mass concentrations of fine particles (PM2.5), particle number concentrations, their size distributions, and CO concentrations in the two rooms, respectively. EC and OC analyses of the particles collected on a quartz filter by cascade impactor were conducted using the thermal optical method. Frying produced higher emissions of fine particles with a wider range of aerodynamic sizes than boiling. Particle spatial distribution was uniform across the rooms during boiling, because emissions were dominated by very fine particle size. It was observed that particle mass size distributions with cut size ≤ 0.25 µm were predominant in all cooking methods. CO concentration was lowest in tofu boiling and about one-tenth of the stove background level. This is possibly due to the absorption of CO by steam cooking.


Keywords: Indoor air pollution; Fine particles; Size distribution; Temporal variation


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

5.9
2020CiteScore
 
 
81st percentile
Powered by
Scopus


Aerosol and Air Quality Research partners with Publons

Special Call for Papers Air Pollution and its impact in South and Southeast Asia

2020 Impact Factor: 3.063
5-Year Impact Factor: 2.857

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.