Yueh-Ping Ku, Caddie Yang, Guan-Yu Lin, Chuen-Jinn Tsai

  • Institute of Environmental Engineering, National Chiao Tung University, No. 1001, University Road, Hsinchu 300, Taiwan

Received: September 30, 2010
Revised: September 30, 2010
Accepted: September 30, 2010
Download Citation: ||https://doi.org/10.4209/aaqr.2010.03.0023  

  • Download: PDF


Cite this article:
Ku, Y.P., Yang, C., Lin, G.Y. and Tsai, C.J. (2010). An Online Parallel-Plate Wet Denuder System for Monitoring Acetic Acid Gas. Aerosol Air Qual. Res. 10: 479-488. https://doi.org/10.4209/aaqr.2010.03.0023


 

ABSTRACT


In air environments, acetic acid gas may lead to irritations, generate pungent odor, and cause objects to corrode. This paper examines an online parallel-plate wet denuder system to monitor gaseous acid at ppbv concentration levels. Denuder surfaces which comprised frosted glass plates coated with a thin layer of TiO2 nanoparticles were covered by a thin film made of ultrapure water or 0.5 mM H2O2 to absorb the test acetic gases that were generated from a small thermostatic evaporation tube. Denuder effluent was then injected automatically into an ion chromatography for real-time detection. The method was validated by comparing measured concentrations with those obtained simultaneously by using a well established impinger technique. Test results showed that the current technique is an efficient collector for gaseous acetic acid, achieving the collection efficiency between 93.8% to 96.4% by using ultrapure water film. It can monitor 0.9–698.0 ppbv gaseous acetic acid accurately in real-time with response time of 10 minutes, a detection limit of 1.2 ppbv and a time resolution of either 10 minutes or 20 minutes, depending on the concentration of the eluent used in the ion chromatography. The technique was applied successfully to measure the exposure concentration of acetic acid gas leaking from a fume hood in a laboratory.


Keywords: Indoor air; Impinger; Ion chromatography; Air quality monitoring; Acidic gas


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

5.9
2020CiteScore
 
 
81st percentile
Powered by
Scopus

2020 Impact Factor: 3.063
5-Year Impact Factor: 2.857

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.