Yee-Lin Wu 1,2, Hsing-Wang Li1,2, Chih-Hsiang Chien1, Yi-Chieh Lai3, Lin-Chi Wang3

  • 1 Department of Environmental Engineering, National Cheng Kung University, Tainan 70101, Taiwan, ROC
  • 2 Sustainable Environment Research Center, National Cheng Kung University, Tainan 70101, Taiwan, ROC
  • 3 Department of Chemical and Materials Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan, ROC

Received: September 30, 2010
Revised: September 30, 2010
Accepted: September 30, 2010
Download Citation: ||https://doi.org/10.4209/aaqr.2010.03.0020  

  • Download: PDF


Cite this article:
Wu, Y.L., Li, H.W., Chien, C.H., Lai, Y.C. and Wang, L.C. (2010). Monitoring and Identification of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans in the Ambient Central Taiwan. Aerosol Air Qual. Res. 10: 463-471. https://doi.org/10.4209/aaqr.2010.03.0020


 

ABSTRACT


Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/Fs) in the ambient air of five sampling sites around central Taiwan were investigated. Principal components analysis (PCA), cluster analysis (CA) and the chemical mass balance (CMB) model were adopted to assess possible PCDD/F sources and their effects on the air quality levels. Field experimental results showed that the mean PCDD/F concentrations in the ambient air were 0.0526, 0.0591, 0.0339 and 0.0727 pg I-TEQ/Nm3 in winter, spring, summer and autumn, respectively. Analysis of atmospheric isopleths for five sampling sites displayed that high PCDD/F concentrations were mostly close to electric arc furnace plants (EAF). Through PCA and CA, the congener profiles of ambient air sampling sites were close to medical waste incinerators (MWI), secondary aluminum smelters (ALS), EAF, waste open burning (OB) and crematories (CM). By using the CMB model, the dominant sources of PCDD/Fs in ambient air were EAF, medical waste incinerator/municipal solid waste incinerators (MWI/MSWI) and unleaded gasoline fuel vehicle/diesel fuel vehicle (UGFV/DFV), which contributed 22–23%, 17–31% and 9–22%, respectively. The above results revealed that ambient air was affected by surrounding PCDD/F sources (MWI, ALS, EAF, CM and OB). However, due to high stack height and low emission concentration, the impact of coal-fired power plant on the PCDD/F levels of ambient air was insignificant.


Keywords: PCDD/Fs; Ambient air; Cluster analysis; Chemical mass balance; Principal components analysis


Don't forget to share this article 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

Latest coronavirus research from Aerosol and Air Quality Research

2018 Impact Factor: 2.735

5-Year Impact Factor: 2.827


SCImago Journal & Country Rank