H. Huang 1, J.J. Cao2, S.C. Lee3, C.W. Zou4, X.G. Chen5, S.J. Fan5

  • 1 School of Chemistry and Environment, South China Normal University, Guangzhou, China
  • 2 Institute of Earth Environment, Chinese Academy of Sciences, Xi’an, China
  • 3 Hong Kong Polytechnic University, Hung Hum, Kowloon, Hong Kong
  • 4 School of Environmental Science and Engineering, NanChang University, Nanchang, China
  • 5 School of Environmental Science and Engineering, Sun Yat Sen University, Guangzhou, China

Received: November 30, 2007
Revised: November 30, 2007
Accepted: November 30, 2007
Download Citation: ||https://doi.org/10.4209/aaqr.2007.03.0018  

  • Download: PDF


Cite this article:
Huang, H., Cao, J., Lee, S., Zou, C., Chen, X. and Fan, S. (2007). Spatial Variation and Relationship of Indoor/Outdoor PM2.5 at Residential Homes in Guangzhou City, China. Aerosol Air Qual. Res. 7: 518-530. https://doi.org/10.4209/aaqr.2007.03.0018


 

ABSTRACT


Fine particles (PM2.5) were measured using Airmetrics mini-volume portable samplers during 2nd July and 13th August, 2004 inside and outside nine homes located in generic urban area, roadside area and industrial plant area in Guangzhou city, China. The indoor and outdoor PM2.5 average concentrations (67.7 and 74.5 µg/m3) were about two times higher than the new guideline of WHO, and higher than the levels in other studies (New York, London, Amsterdam, Brisbane, Osaka and Hong Kong, etc). Both indoor and outdoor average PM2.5 concentrations in roadside area (73.5 and 79.4 µg/m3) and in industrial plant area (73.4 and 92.9 µg/m3) were higher than those in generic urban area (56.2 and 51.2 µg/m3). The average I/O ratio in generic urban area, roadside area and industrial plant area were 1.10, 0.93 and 0.79, respectively. The indoor/outdoor correlations of PM2.5 in generic urban area, roadside area and industrial area were from strong (R2 = 0.70, p < 0.001, n = 11) to moderate (R2 = 0.54, p = 0.007, n = 12) and to poor (R2 = 0.17, p = 0.088, n = 12). Strong indoor/outdoor PM2.5 correlation with I/O > 1 in generic urban area indicated excellent ventilation condition at there, good indoor/outdoor PM2.5 correlation with I/O < 1 in roadside area suggested that the indoor PM2.5 were mainly from the outdoor air, and poor indoor/outdoor PM2.5 correlation in industrial plant area was ascribed to seldom ventilation in one home (IS2).


Keywords: PM2.5; Residential Homes; Indoor air quality; I/O ratio


Share this article with your colleagues 

 

Subscribe to our Newsletter 

Aerosol and Air Quality Research has published over 2,000 peer-reviewed articles. Enter your email address to receive latest updates and research articles to your inbox every second week.

7.3
2022CiteScore
 
 
77st percentile
Powered by
Scopus
 
   SCImago Journal & Country Rank

2022 Impact Factor: 4.0
5-Year Impact Factor: 3.4

Call for Papers for the special issue on: "Carbonaceous Aerosols in the Atmosphere"

Aerosol and Air Quality Research partners with Publons

CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit
CLOCKSS system has permission to ingest, preserve, and serve this Archival Unit

Aerosol and Air Quality Research (AAQR) is an independently-run non-profit journal that promotes submissions of high-quality research and strives to be one of the leading aerosol and air quality open-access journals in the world. We use cookies on this website to personalize content to improve your user experience and analyze our traffic. By using this site you agree to its use of cookies.