Performance of Four Consumer-grade Air Pollution Measurement Devices in Different Residences

Category: Others

Article In Press
DOI: 10.4209/aaqr.2019.01.0045
PDF | Supplemental material

Export Citation:  RIS | BibTeX

To cite this article:
Manibusan, S. and Mainelis, G. (2019). Performance of Four Consumer-grade Air Pollution Measurement Devices in Different Residences. Aerosol Air Qual. Res., doi: 10.4209/aaqr.2019.01.0045.

Sydonia Manibusan, Gediminas Mainelis

  • Department of Environmental Sciences, Rutgers University, New Brunswick, NJ 08901, USA

Highlights

  • Four consumer-grade PM2.5 monitors were assessed in multiple residences.
  • Compared to reference Pearson correlation of the monitors ranged from –0.028 to 0.87.
  • Low-cost monitors tested were significantly different from the filter-based method.
  • Low-cost monitors should be calibrated for environment and particles of interest.

Abstract

There has been a proliferation of inexpensive consumer-grade devices for monitoring air pollutants, including PM2.5 and certain gasses. This study compared the performance of four consumer-grade devices—the Air Quality Egg 2 (AQE2), BlueAir Aware, Foobot, and Speck—that utilize optical sensors to measure the PM2.5 concentration. The devices were collocated and operated for 7 days in each of three residences, and the PM2.5 mass concentrations were compared with those measured by established optical sensing devices, viz., the personal DataRAM and DustTrak DRX, as well as the filter-based Personal Modular Impactor (PMI).

Overall, the Foobot and BlueAir displayed the strongest correlations with the direct-reading reference instruments for both the hourly and daily PM2.5 mass concentrations. Comparing the 1-hour averages obtained with the DustTrak DRX for all of the residences with those obtained with the Foobot, BlueAir, AQE2, and Speck, the Pearson’s correlation coefficients (R’s) were 0.80, 0.88, –0.028, and 0.60, respectively. Overall, the strength of the correlation depended on the specific residence, likely due to the differences in aerosol composition. The correlations with the PMI measurements were moderate, with R values of 0.44 and 0.56 for the BlueAir and Foobot, respectively. The correlation coefficients for the daily values obtained with the AQE2 and Speck were –0.59 and 0.70 compared to the PMI. According to a paired t-test, the average 24-h PM2.5 concentration data obtained using the consumer-grade monitors were statistically different (p > 0.05) from the mass values measured by the gravimetric filters. Overall, this study demonstrates the ability of consumer-grade air pollution monitors to report PM2.5 trends accurately; however, for accurate mass concentration measurements, these monitors must be calibrated for a particular location and application. Further testing is needed to determine their suitability for long-term indoor field studies.

Keywords

Low-cost monitors PM2.5 Indoor air


Related Article

Component Characteristics and Emission Factors of Volatile Organic Compounds from Dyestuff Production

Yan Lu, Yixin Shao, Ruiyang Qu, Chenghang Zheng , Yongxin Zhang, Wenhao Lin, Weihong Wu, Yuanqun Feng, Xiang Gao
Accepted Manuscripts
DOI: 10.4209/aaqr.2019.09.0474
PDF

Patterns and Sources of PM10 in the Ecologically Sensitive Himalayan Region in Himachal Pradesh, India

Raman Kumar, Jui-Huan Lee, Ruei-Hao Shie, Chia-Pin Chio, Chang-Chuan Chan
Accepted Manuscripts
DOI: 10.4209/aaqr.2019.03.0133
PDF

Biogenic Volatile Organic Compound (BVOC) Emissions from Various Endemic Tree Species in Turkey

Baris Yaman, Yagmur Meltem Aydin, Husnu Koca, Okan Dasdemir, Melik Kara, Hasan Altiok, Yetkin Dumanoglu, Abdurrahman Bayram, Doganay Tolunay, Mustafa Odabasi, Tolga Elbir
;