OPEN ACCESS

Articles online

Quantity, Size Distribution, and Characteristics of Cough-generated Aerosol Produced by Patients with an Upper Respiratory Tract Infection

Category: Air Pollution and Health Effects

Volume: 19 | Issue: 4 | Pages: 840-853
DOI: 10.4209/aaqr.2018.01.0031
PDF

Export Citation:  RIS | BibTeX

Jinho Lee1, Danbi Yoo1, Seunghun Ryu1, Seunghon Ham2, Kiyoung Lee1,3, Myoungsouk Yeo4, Kyoungbok Min5, Chungsik Yoon 1,3

  • 1 Department of Environmental Health Sciences, Seoul National University Graduate School of Public Health, Seoul 08826, Korea
  • 2 Department of Occupational Environmental Medicine, Gachon University Gil Medical Center, College of Medicine, Gachon University, Incheon 21936, Korea
  • 3 Institute of Health and Environment, Seoul National University Graduate School of Public Health, Seoul 08826, Korea
  • 4 Department of Architecture and Architectural Engineering, College of Engineering, Seoul National University, Seoul 08826, Korea
  • 5 Department of Preventive Medicine, College of Medicine, Seoul National University, Seoul 03080, Korea

Highlights

  • Most particles generated from coughing were small enough to float in the air.
  • Particles during coughing could be transmitted in the air as far as three meters.
  • 2 m cut-off rule for prevention air infection should be reconsidered.

Abstract

It is generally recognized that most nosocomial infections are spread by exposure to expelled particles at close range (usually within 1 m) or through contact. Although the Korea Centers for Disease Control established a 2-m cut-off for transmittance from patients during the Middle East Respiratory Syndrome (MERS) outbreak in Korea in 2015, questions have been raised regarding possible infection due to aerosols transported beyond this distance. The aim of this study was to characterize cough-generated aerosol emissions from cold patients and to determine the transmission distance of cough particles in indoor air. The study was conducted using subjects with acute upper respiratory infections. The number and size distribution of the particles generated from each cough were measured after participants coughed into a stainless steel chamber in a clean room. The total particle concentration was measured for each subject in the near field (< 1 m) and far field (> 2 m). The number of particles emitted by the cough of an infected patient was 560 ± 5513% greater than that generated by patients after recovery (P < 0.001). The number of particles was also significantly higher (P < 0.001) than the background concentration when infected patients were coughing, even in the far field. These results suggest that the 2-m cut-off should be reconsidered to effectively prevent airborne infections.

Keywords

Cough aerosol Airborne transmission Respiratory infections Disease transmission Droplet nuclei


Related Article

Source Identification on High PM2.5 Days Using SEM/EDS, XRF, Raman, and Windblown Dust Modeling

Jeff Wagner , Zhong-Min Wang, Sutapa Ghosal, Stephen Wall
Accepted Manuscripts
DOI: 10.4209/aaqr.2019.05.0276
PDF

Analysis of PAHs Associated with PM10 and PM2.5 from Different Districts in Nanjing

Xiansheng Liu, J├╝rgen Schnelle-Kreis, Brigitte Schloter-Hai, Lili Ma , Pengfei Tai, Xin Cao, Cencen Yu, Thomas Adam, Ralf Zimmermann

Traffic Condition and Emission Factor from Diesel Vehicles within the Kathmandu Valley

Enna Mool, Prakash V. Bhave, Nita Khanal, Rejina M. Byanju, Sagar Adhikari, Bhupendra Das, Siva P. Puppala

Comparative Study of PAHs in PM1 and PM2.5 at a Background Site in the North China Plain

Yan Zhang, Lingxiao Yang , Ying Gao, Jianmin Chen, Yanyan Li, Pan Jiang, Junmei Zhang, Hao Yu, Wenxing Wang
;