Effect of Aerosol Loading on Separation Performance of PM2.5 Cyclone Separators

Category: Aerosol Physics and Instrumentation

Accepted Manuscripts
DOI: 10.4209/aaqr.2017.11.0458
PDF | RIS | BibTeX

Chih-Wei Lin1, Ting-Ju Chen1, Sheng-Hsiu Huang1, Yu-Mei Kuo 2, Hua-Qiao Gui3, Chih-Chieh Chen1

  • 1 Graduate Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei 10055, Taiwan
  • 2 Department of Occupational Safety and Health, Chung Hwa University of Medical Technology, Tainan 71703, Taiwan
  • 3 Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China


The cyclone performance begins to deteriorate just as aerosol loading initiates.
Larger solid particles have a minor impact on the cyclone.
Cyclone size does not affect aerosol loading characteristics.
Particle sizes close to the cut-point show worst loading effect.


Increasing attention has been drawn to the adverse health effects of particulate matter less than 2.5 µm (PM2.5) over the past several decades. To obtain reliable PM2.5 measurements, it is critical to efficiently separate particulate matter less than 2.5 µm in the airstream from the beginning to the end of sampling. However, commonly used separators for PM2.5 monitoring, such as the BGI Very Sharp Cut Cyclone (VSCC), are usually subject to aerosol loading effects. This study investigates the loading effect on cyclone separation performance as a function of particle size, cyclone size, particle material, and air humidity. Based on the ratios of dimensions to the body diameter of the BGI VSCC, four cyclones with different body diameters (13–35.6 mm) are fabricated. An ultrasonic atomizer is employed to generate micrometer-sized potassium sodium tartrate (PST) particles and sodium chloride (NaCl) particles as solid challenge particles and di-ethyl-hexyl-sebacate (DEHS) particles as liquid ones. Aerosol particles are neutralized to the Boltzmann charge equilibrium. An aerodynamic particle sizer measures the aerosol distributions and number concentrations upstream and downstream of the cyclones. The experimental results show that solid particles such as PST with sizes close to the cyclone cut-point exhibit a significant loading effect. However, no significant difference is found on aerosol loading effect on four different-sized cyclones. The cyclone separation curve appears to shift toward smaller sizes due to aerosol loading. During the loading test, the aerosol penetration of 2.5-µm particles abruptly decreased, from 50%, at the first 20 minutes to a relatively stable level of 30%, an average decrease of 20%. Thus the performance of cyclone PM2.5 samplers with progressive aerosol loading might result in an underestimation of PM2.5, particularly for continuous monitoring of particulate matter.


Aerosol loading Size-selective separator Cyclone Continuous aerosol monitoring

Related Article

A Comparison of PAH Emission Sampling Methods (Cyclone, Impactor) in Particulate and Gaseous Phase

Jiří Horák, Lenka Kuboňová , Kamil Krpec, František Hopan, Petr Kubesa, Jan Koloničný, Daniela Plachá

Development of a High-Volume PM2.5 Particle Sampler Using Impactor and Cyclone Techniques

Tomoaki Okuda , Ryoma Isobe, Yusuke Nagai, Shunichi Okahisa, Koji Funato, Kozo Inoue
Volume: 15 | Issue: 3 | Pages: 759-767
DOI: 10.4209/aaqr.2014.09.0194