OPEN ACCESS

Articles online

Inter-Laboratory Validation of the Method to Determine the Filtration Efficiency for Airborne Particles in the 3–500 nm Range and Results Sensitivity Analysis

Category: Special Issue for the 12th World Filtration Congress

Volume: 17 | Issue: 11 | Pages: 2669-2680
DOI: 10.4209/aaqr.2017.03.0104
PDF | Supplemental material | RIS | BibTeX

Panagiota Sachinidou1,2, Yeon Kyoung Bahk1,2, Min Tang3, Ningning Zhang3, Shawn S.C. Chen3, David Y.H. Pui3, Bruno Araújo Lima4, Gabriele Bosco4, Paolo Tronville4, Thomas Mosimann5, Mikael Eriksson6, Jing Wang 1,2

  • 1 Laboratory of Advanced Analytical Technologies, Empa, 8600 Dubendorf, Switzerland
  • 2 Institute of Environmental Engineering, ETH Zurich, 8093 Zurich, Switzerland
  • 3 Particle Technology Laboratory, Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55414, USA
  • 4 Department of Energy, Politecnico di Torino, 10129 Torino, Italy
  • 5 Unifil AG, Filtertechnik, CH-5702 Niederlenz, Switzerland
  • 6 Camfil Svenska AB, SE-619 33 TROSA, Sweden

Highlights

Filtration tests for ISO standard.
< 20% deviation in filtration efficiency.
Ambient factors have marginal effects.


Abstract

The filtration of airborne nanoparticles is becoming an important issue as they are produced in large quantities from material synthesis and combustion emission. Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media for airborne nanoparticles down to a single-digit nanometer range.

An inter-laboratory evaluation is performed under the Technical Committee 195 of European Committee for Standardization (CEN/TC195) for the development of the methodology to determine effectiveness of filtration media for airborne particles in the 3–500 nm range. Statistical analysis of the results was performed according to ISO 5725-2 in order to evaluate the test procedure and sensitivity analysis was carried out to identify the factors that could possibly affect the test results.

Inter-laboratory analysis revealed some deviation among the experimental results. The statistical analysis showed a less than 20% deviation. This deviation could be attributed to the difference among the experimental setups used by the laboratories. The sensitivity analyses did not indicate a strong influence by the temperature, relative humidity, flow distribution, challenging particle concentration, or particle density on the filtration efficiency in the parameter ranges used in the inter-laboratory test. However, the charging status of the filter affected the filtration efficiency.

Keywords

Filtration efficiency Inter-laboratory tests Sensitivity analysis Statistical analysis


Related Article

Health Risk Assessment and Correlation Analysis on PCDD/Fs in the Fly Ash from a Municipal Solid Waste Incineration Plant

Yen-Kung Hsieh, Wei-Sheng Chen , Jinning Zhu , Yi-Jing Wu, Qianli Huang
Volume: 18 | Issue: 3 | Pages: 734-748
DOI: 10.4209/aaqr.2017.12.0587
PDF | Supplemental material

Sensitivity Analysis of PM2.5-Bound Total PCDD/Fs-TEQ Content: In the Case of Wuhu City, China

Weiwei Wang, Kangping Cui , Rong Zhao, Jinning Zhu , Qianli Huang, Wen-Jhy Lee
Volume: 18 | Issue: 2 | Pages: 407-420
DOI: 10.4209/aaqr.2017.11.0507
PDF

On the Special Issue for the 12th World Filtration Congress

David Y.H. Pui, Wilhelm Höflinger, Jing Wang, Chuen-Jinn Tsai
Volume: 17 | Issue: 11 | Pages: 2643-2644
DOI: 10.4209/aaqr.2017.09.0332
PDF

Study of Flow Patterns in Two-Stage Mode of Moving Granular Bed Filter

Chia-Wei Chang, Shu-San Hsiau , Yi-Shun Chen, Yan-Pin Chyou, Jiri Smid
Volume: 17 | Issue: 11 | Pages: 2691-2704
DOI: 10.4209/aaqr.2016.12.0588
PDF
;