OPEN ACCESS

Articles online

A Low-Cost Device for Bulk Sampling of Airborne Particulate Matter: Evaluation of an Ionic Charging Device

Category: Aerosol Physics and Instrumentation

Volume: 17 | Issue: 6 | Pages: 1452-1462
DOI: 10.4209/aaqr.2016.09.0423
PDF | Supplemental material | RIS | BibTeX

Nima Afshar-Mohajer1, Wesley H. Godfrey1, Ana M. Rule1, Elizabeth C. Matsui2, Julian Gordon3, Kirsten Koehler 1

  • 1 Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA
  • 2 Department of Pediatrics, Johns Hopkins School of Medicine, Baltimore, MD 21205, USA
  • 3 Inspirotec Inc., Chicago, IL 60647, USA

Highlights

Ion-charging devices (ICDs) are ideal bulk aerosol samplers.
ICDs underestimate aerosol concentrations compared to conventional samplers.
ICDs provide up to 9x greater mass of particles that the conventional aerosol samplers.
Particle collection performance strongly depends on particles chargeability.
ICDs roughly estimate PM concentration via linear correlations to other samplers.


Abstract

Bulk sampling of aerosols is often needed for the determination of physical properties, chemical composition and toxicity assessments of airborne particulate matter. Conventional aerosol samplers have several limitations for use as bulk aerosol collectors including cost, noise levels, power requirements associated with the use of a pump, limited flow rate, and a relatively long sampling time needed to collect sufficient mass to achieve gravimetric or other method limits of detection. In this study, a low-cost ionic charging device (ICD) was evaluated that addresses many of the drawbacks of conventional aerosol samplers. Different types of particles including incense fume, Arizona Road Dust (ARD) powders and Polystyrene Latex (PSL) spheres of different sizes were aerosolized then sampled using three ICDs and compared to conventional inhalable and PM2.5 (particulate matter with aerodynamic diameter less than 100 µm and 2.5 µm, respectively) aerosol samplers in a controlled laboratory chamber at varying concentrations. The device was also evaluated in indoor environments. ICDs operate at almost 18.5 times higher flow rate than conventional personal samplers and provided up to 9 times greater total collected mass compared to the conventional samplers over the same time frame. Using a regression analysis, aerosol-specific linear equations with slopes (CPM2.5/CICD) from 1.21 to 7.10 and R2 from 0.74 to 0.99 for estimating the inhalable and PM2.5 mass concentrations using the ICD were derived. This study suggests that the ICD provides a less accurate estimate of size-selective PM mass concentrations than conventional personal aerosol samplers; however, it collects coarse particles efficiently and increases total sampled mass per time at a lower cost and without noise associated with traditional sampling methods. Therefore, the ICD can be used as a bulk aerosol collector for composition analyses and in-vitro toxicology tests of coarse PM.

Keywords

Bulk aerosol sampling Inhalable aerosol sampler PM2.5 aerosol sampler Coarse PM Indoor air


Related Article

Assessment of Indoor Bioaerosols in Public Spaces by Real-Time Measured Airborne Particles

Hsiao-Lin Huang , Mei-Kuei Lee, Hao-Wun Shih
Volume: 17 | Issue: 9 | Pages: 2276-2288
DOI: 10.4209/aaqr.2017.02.0089
PDF

Analysis of Aerosol Composition and Assessment of Tunnel Washing Performance within a Mass Rapid Transit System in Taiwan

Ying-Yi Chen, Chung-Yen Lu, Pei-Chun Chen, I-Fang Mao, Mei-Lien Chen
Volume: 17 | Issue: 6 | Pages: 1527-1538
DOI: 10.4209/aaqr.2017.03.0120
PDF | Supplemental material

Fog Water Collection Effectiveness: Mesh Intercomparisons

Daniel M. Fernandez , Alicia Torregrosa, Peter S. Weiss-Penzias, Bong June Zhang, Deckard Sorensen, Robert E. Cohen, Gareth McKinley, Justin Kleingartner, Andrew Oliphant, Matthew Bowman
Accepted Manuscripts
DOI: 10.4209/aaqr.2017.01.0040
PDF
;