Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators

Category: Control Techniques and Strategy

Volume: 17 | Issue: 5 | Pages: 1305-1315
DOI: 10.4209/aaqr.2016.09.0390
PDF | RIS | BibTeX

Norbert Serfozo 1, Jakub Ondráček2, Naděžda Zíková2, Mihalis Lazaridis1, Vladimír Ždímal2

  • 1 School of Environmental Engineering, Technical University of Crete, Polytechneioupolis, 73100 Chania, Greece
  • 2 Institute of Chemical Process Fundamentals, v.v.i., Academy of Sciences of the Czech Republic, Rozvojová 135, 16502 Prague, Czech Republic

Highlights

Size-resolved penetration (CMD) of 13 CE-marked FFRs were measured experimentally.
47 mm filters were cut out and challenged with monodisperse ammonium sulfate.
Two filters from same FFR and two identical half masks from each FFR were examined.
Methodology of currently valid EN149:2001 was compared to our size-resolved method.


Abstract

Throughout the years, the performance of the FFRs has been the topic of extensive studies, resulting mainly in the characterization of aerosol penetration through filters using aerosols that are thought to be similar to those encountered in workplaces. There are limited number of studies in the literature reporting CE-marked respirator performance, and there is a need to perform a penetration evaluation of CE-marked respirators through all 3 filtering classes: FFP1 (80%), FFP2 (94%), and FFP3 (99%). In this study, the percentage penetrations and the most penetrating particle size (MPPS) of 47 mm filters cut out from 13 different CE-marked respirator half masks (2 samples of each FFR) were evaluated size-selectively using nine sizes of charge-neutralized monodisperse aerosol, which ranged from 20 to 400 nm (CMD). Comparison of the penetrations at MPPS from all the examined filters showed that the percentage penetration ranged 3.2–16.3% (FFP1), 2.4–34.3% (FFP2), and 0.02–3.3% (FFP3). Experimental data also revealed that the penetration difference between 2 samples from the same respirator was in most cases up to 6.8%, and between 2 identical respirators up to 2.5%. The MPPS was found to be between 30 and 60 nm (CMD) in all measurements. By comparing the obtained results to the European Standard we conclude that the standard method underestimates particle penetration (especially for particles < 100 nm) due to the usage of non neutralized, polydisperse test aerosol, detection methods burdened with measurement artifacts, and the assumption that the MPPS is at ≈ 600 nm (MMD) as the criterion for filtering facepieces to pass the penetration test.

Keywords

Size-resolved penetration CE-marked respirator Monodisperse ammonium sulfate 47 mm filter sample EN 149


Related Article

Ozone Catalytic Oxidation of Gaseous Toluene over MnO2-Based Ozone Decomposition Catalysts Immobilized on a Nonwoven Fabric

Kazuhiko Sekiguchi , Yuki Kurita, Kenshi Sankoda, Norikazu Namiki, Fumio Yasui, Hajime Tamura
Accepted Manuscripts
DOI: 10.4209/aaqr.2017.01.0045
PDF

Novel Method for Preparing Controllable Nanoporous α-Fe2O3 and its Reactivity to SCR De-NOx

Haibo Liu, Zexin Zhang, Qian Li, Tianhu Chen , Changai Zhang, Dong Chen, Chengzhu Zhu, Yang Jiang
Volume: 17 | Issue: 7 | Pages: 1898-1908
DOI: 10.4209/aaqr.2017.05.0188
PDF

Effects of Nutrient Availability on the Biomass Production and CO2 Fixation in a Flat Plate Photobioreactor

Chih Ming Su, Hsin Ta Hsueh, Chi Ming Tseng, Dah Tong Ray, Yun Hwei Shen, Hsin Chu
Volume: 17 | Issue: 7 | Pages: 1887-1897
DOI: 10.4209/aaqr.2016.09.0386
PDF | Supplemental material

Removal of DPM from an Air Stream Using Micron-Scale Droplets

Lucas Rojas-Mendoza, Emily A. Sarver , John R. Saylor
Volume: 17 | Issue: 7 | Pages: 1865-1874
DOI: 10.4209/aaqr.2017.03.0093
PDF | Supplemental material
;