OPEN ACCESS

Articles online

Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators

Category: Control Techniques and Strategy

Volume: 17 | Issue: 5 | Pages: 1305-1315
DOI: 10.4209/aaqr.2016.09.0390
PDF | RIS | BibTeX

Norbert Serfozo 1, Jakub Ondráček2, Naděžda Zíková2, Mihalis Lazaridis1, Vladimír Ždímal2

  • 1 School of Environmental Engineering, Technical University of Crete, Polytechneioupolis, 73100 Chania, Greece
  • 2 Institute of Chemical Process Fundamentals, v.v.i., Academy of Sciences of the Czech Republic, Rozvojová 135, 16502 Prague, Czech Republic

Highlights

Size-resolved penetration (CMD) of 13 CE-marked FFRs were measured experimentally.
47 mm filters were cut out and challenged with monodisperse ammonium sulfate.
Two filters from same FFR and two identical half masks from each FFR were examined.
Methodology of currently valid EN149:2001 was compared to our size-resolved method.


Abstract

Throughout the years, the performance of the FFRs has been the topic of extensive studies, resulting mainly in the characterization of aerosol penetration through filters using aerosols that are thought to be similar to those encountered in workplaces. There are limited number of studies in the literature reporting CE-marked respirator performance, and there is a need to perform a penetration evaluation of CE-marked respirators through all 3 filtering classes: FFP1 (80%), FFP2 (94%), and FFP3 (99%). In this study, the percentage penetrations and the most penetrating particle size (MPPS) of 47 mm filters cut out from 13 different CE-marked respirator half masks (2 samples of each FFR) were evaluated size-selectively using nine sizes of charge-neutralized monodisperse aerosol, which ranged from 20 to 400 nm (CMD). Comparison of the penetrations at MPPS from all the examined filters showed that the percentage penetration ranged 3.2–16.3% (FFP1), 2.4–34.3% (FFP2), and 0.02–3.3% (FFP3). Experimental data also revealed that the penetration difference between 2 samples from the same respirator was in most cases up to 6.8%, and between 2 identical respirators up to 2.5%. The MPPS was found to be between 30 and 60 nm (CMD) in all measurements. By comparing the obtained results to the European Standard we conclude that the standard method underestimates particle penetration (especially for particles < 100 nm) due to the usage of non neutralized, polydisperse test aerosol, detection methods burdened with measurement artifacts, and the assumption that the MPPS is at ≈ 600 nm (MMD) as the criterion for filtering facepieces to pass the penetration test.

Keywords

Size-resolved penetration CE-marked respirator Monodisperse ammonium sulfate 47 mm filter sample EN 149


Related Article

Improved Photocatalytic Air Cleaner with Decomposition of Aldehyde and Aerosol-Associated Influenza Virus Infectivity in Indoor Air

Kimiyasu Shiraki , Hiroshi Yamada, Yoshihiro Yoshida, Ayumu Ohno, Teruo Watanabe, Takafumi Watanabe, Hiroyuki Watanabe, Hidemitsu Watanabe, Masao Yamaguchi, Fumio Tokuoka, Shigeatsu Hashimoto, Masakazu Kawamura, Norihisa Adachi
Volume: 17 | Issue: 11 | Pages: 2901-2912
DOI: 10.4209/aaqr.2017.06.0220
PDF

High Selectivity of Visible-Light-Driven La-doped TiO2 Photocatalysts for NO Removal

Yu Huang, Jun-Ji Cao, Fei Kang, Sheng-Jie You, Chia-Wei Chang, Ya-Fen Wang
Volume: 17 | Issue: 10 | Pages: 2555-2565
DOI: 10.4209/aaqr.2017.08.0282
PDF

Laboratory Evaluation of a Manure Additive for Mitigating Gas and Odor Releases from Layer Hen Manure

Ji-Qin Ni , Albert J. Heber, Teng T. Lim, Sam M. Hanni, Claude A. Diehl
Volume: 17 | Issue: 10 | Pages: 2533-2541
DOI: 10.4209/aaqr.2016.07.0327
PDF
;